EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Technical ultrasonic quality assurance in Danish Radiology Departments

Karen Brage, Kristina T.T. Pank, Sisse Hansen, Lis K. Sondergaard, Mark F. McEntee, Malene Roland V. Pedersen

WFUMB Ultrasound Open · 2023

DOI: 10.1016/j.wfumbo.2023.100005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift WFUMB Ultrasound Open, 2023. Verfasst von Karen Brage und 5 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In general, there is a lack of technical quality assurance (TQA) in ultrasound, which threatens patients. This study aimed to map the level of ultrasound quality assurance in Danish Radiology Departments, assess the intra- and interrater reliability of the in-air method for evaluating transducer quality, and determine the prevalence of faulty transducers. From October to November 2021, an anonymous survey focused on the extent of TQA was e-mailed to clinicians (via managers) responsible for ultrasound TQA. The six-item survey included both closed and open-ended questions. In addition, a sample of 63 ultrasound b-mode reverberation images was collected from four Danish Radiological Departments, later rated by two blinded radiographers on a dichotomous scale. A total of 46 participants responded to the survey. In the survey, 15 respondents reported not having a TQA procedure, while six thought a procedure existed but were uncertain. Various methods were reported for the respondents who answered that TQA was performed (n = 13). Half of the respondents (n = 23, 50%) reported experiencing transducer malfunctions, and seven said they did not find the lack of regular testing problematic. The interrater reliability was κ = 0.75 (95% CI.: 0.61–0.89), and the inter-rater reliability was κ = 0.84 (95% CI.: 0.70–0.98). Based on the agreement between the two raters, 20 out of 50 (40%) transducers were flawed. This study demonstrates the general deficiency of TQA in Danish Radiological Departments, with 21 clinicians responsible for ultrasound TQA responding either not having a TQA procedure or being uncertain if one exists. Furthermore, the study reveals that the in-air method for assessing transducer quality demonstrates moderate to almost perfect reliability and that nearly half of the transducer tested exhibits visual faults.

Zitieren

APA

Brage, K., Pank, K. T., Hansen, S., Sondergaard, L. K., McEntee, M. F., & Pedersen, M. R. V. (2023). Technical ultrasonic quality assurance in Danish Radiology Departments. WFUMB Ultrasound Open. https://doi.org/10.1016/j.wfumbo.2023.100005

Vancouver

Brage K, Pank KT, Hansen S, Sondergaard LK, McEntee MF, Pedersen MRV. Technical ultrasonic quality assurance in Danish Radiology Departments. WFUMB Ultrasound Open. 2023. doi:10.1016/j.wfumbo.2023.100005

BibTeX
@article{Brage2023,
  author = {Brage, Karen and Pank, Kristina T.T. and Hansen, Sisse and Sondergaard, Lis K. and McEntee, Mark F. and Pedersen, Malene Roland V.},
  title = {Technical ultrasonic quality assurance in Danish Radiology Departments},
  journal = {WFUMB Ultrasound Open},
  year = {2023},
  doi = {10.1016/j.wfumbo.2023.100005}
}
Kostenlos starten →