EUVIMEDEUVIMED entdecken
Crossref

Carbon Monoxide Levels Produced by Propane/Isobutane Canister Stoves inside a Tent

Jeffrey T Thurman, Rebecca Leavitt, James T Buchanan, Jacob Shreffler, Martin R Huecker, Todd Early

Wilderness & Environmental Medicine · 2023

DOI: 10.1016/j.wem.2023.06.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Wilderness & Environmental Medicine, 2023. Verfasst von Jeffrey T Thurman und 5 weiteren Autor:innen. Beteiligte Einrichtung: University of Louisville, Department of Emergency Medicine, Louisville, KY. Electronic address: jthurman06@gmail.com. Hauptthemen laut MEDLINE: Carbon Monoxide, Air Pollution, Indoor. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 7 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Improper use of camp stoves in enclosed spaces has resulted in fatalities from carbon monoxide (CO) poisoning. Prior research has focused on the CO output of stoves burning white gas, unleaded gas, or kerosene. Stoves burning an isobutane/propane fuel have not been investigated and are the focus of this study.

Methods

Three stoves utilizing isobutane/propane fuel were used to heat a pot of water inside a 3-season tent under controlled settings. Multiple runs with each stove were performed, and CO measurements, in parts per million (ppm), were recorded at 1-min intervals for a total of 15 min using a RAE Systems gas monitor. Data are reported as mean with SD. Repeated measures analysis of variance was utilized to examine changes over time. Statistical significance was set at P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carbon MonoxideAir Pollution, IndoorHumansPropaneCooking

Stichwörter der Autor:innen

air qualityasphyxiant gas toxicitybackpackingcampingenclosed spaceproducts of combustion

Substanzen

Carbon MonoxidePropane

Autor:innen und Institutionen

  • University of Louisville, Department of Emergency Medicine, Louisville, KY. Electronic address: jthurman06@gmail.com.
  • University of Louisville, Department of Emergency Medicine, Louisville, KY.
  • Buechel Fire-EMS, Louisville, KY.

Zitieren

APA

Thurman, J. T., Leavitt, R., Buchanan, J. T., Shreffler, J., Huecker, M. R., & Early, T. (2023). Carbon Monoxide Levels Produced by Propane/Isobutane Canister Stoves inside a Tent. Wilderness & Environmental Medicine. https://doi.org/10.1016/j.wem.2023.06.006

Vancouver

Thurman JT, Leavitt R, Buchanan JT, Shreffler J, Huecker MR, Early T. Carbon Monoxide Levels Produced by Propane/Isobutane Canister Stoves inside a Tent. Wilderness & Environmental Medicine. 2023. doi:10.1016/j.wem.2023.06.006

BibTeX
@article{Thurman2023,
  author = {Thurman, Jeffrey T and Leavitt, Rebecca and Buchanan, James T and Shreffler, Jacob and Huecker, Martin R and Early, Todd},
  title = {Carbon Monoxide Levels Produced by Propane/Isobutane Canister Stoves inside a Tent},
  journal = {Wilderness & Environmental Medicine},
  year = {2023},
  doi = {10.1016/j.wem.2023.06.006}
}
Kostenlos starten →