Fachartikel in der Zeitschrift Vision Research, 2024. Verfasst von Bhagya Lakshmi Marella und 4 weiteren Autor:innen. Beteiligte Einrichtung: Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Road 2 Banjara Hills, Hyderabad 500034, Telangana, India; Prof. Br…. Hauptthemen laut MEDLINE: Visual Acuity, Keratoconus, Corneal Wavefront Aberration. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 62 Literaturangaben.
Abstract (Originalsprache)
Contrast demodulation and phase distortions are exaggerated in retinal images blurred by the higher-order wavefront aberrations of keratoconic eyes. While the performance loss from the former parameter is well understood, little is known about the impact of the latter on visual functions in this disease condition. The present study investigated the impact of phase distortions on the monocular logMAR visual acuity, letter discriminability and random-dot stereoacuity of seventeen visually healthy adults (ten for visual acuity and letter discriminability; ten for stereoacuity and three common to both experiments) using images that were computationally blurred by four different higher-order wavefront aberration profiles of keratoconic eyes that showed significant distortions in the phase spectrum. Participants viewed these images through 2 mm artificial pupils to negate their native ocular wavefront aberrations. The results showed progressive losses in visual acuity and stereoacuity with increasing blur, a third of which could be recovered following phase nullification. Letter discriminability also improved following phase nullification, more so for smaller than larger optotypes. Stereoacuity loss and, consequently, its recovery following phase nullification was more prominent for profiles simulating unilateral asymmetric keratoconus than for profiles simulating bilateral symmetric keratoconus. These results agree with previous reports obtained from blur induced with lower-order aberrations and indicate that a similar trend may be observed for more complex patterns of blur like keratoconus. Overall, both contrast demodulation and misalignment of the local features of the blurred image may contribute to losses of spatial and depth vision in keratoconus. Phase nullification may partially mitigate these losses, thereby allowing the processing of finer spatial details and veridical disparity estimations for improved depth perception.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Road 2 Banjara Hills, Hyderabad 500034, Telangana, India; Prof. Brien Holden Eye Research Centre, L V Prasad Eye Institute, Road 2 Banja…
- Centre for Applied Vision Research, City, University of London, Northampton Square, London EC1V 0HB, United Kingdom.
- Shantilal Sanghvi Cornea Institute, L V Prasad Eye Institute, Road no. 2, Banjara Hills, Hyderabad 500034, Telangana, India.
Zitieren
APA
Lakshmi Marella, B., Conway, M. L., Vaddavalli, P. K., Suttle, C. M., & Bharadwaj, S. R. (2024). Optical phase nullification partially restores visual and stereo acuity lost to simulated blur from higher-order wavefront aberrations of keratoconic eyes. Vision Research. https://doi.org/10.1016/j.visres.2024.108486
Vancouver
Lakshmi Marella B, Conway ML, Vaddavalli PK, Suttle CM, Bharadwaj SR. Optical phase nullification partially restores visual and stereo acuity lost to simulated blur from higher-order wavefront aberrations of keratoconic eyes. Vision Research. 2024. doi:10.1016/j.visres.2024.108486
BibTeX
@article{LakshmiMarella2024,
author = {Lakshmi Marella, Bhagya and Conway, Miriam L and Vaddavalli, Pravin K and Suttle, Catherine M and Bharadwaj, Shrikant R},
title = {Optical phase nullification partially restores visual and stereo acuity lost to simulated blur from higher-order wavefront aberrations of keratoconic eyes},
journal = {Vision Research},
year = {2024},
doi = {10.1016/j.visres.2024.108486}
}
EUVIMED