EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Combining an anaesthetic conserving device with a circle breathing system to minimise isoflurane waste: an in vitro study

Jana Flyps, Maarten Haspeslagh, Stefaan Bouchez, Jan F A Hendrickx, Andreas Meiser, Stijn Schauvliege

Veterinary Anaesthesia and Analgesia · 2026-11 · 53 (6) · 101370

DOI: 10.1016/j.vaa.2026.101370 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Anaesthesia and Analgesia, 2026-11. Verfasst von Jana Flyps und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Large Animal Surgery, Anaesthesia and Orthopaedics, Faculty of Veterinary Medicine, Ghent University, Merelbeke-Melle, Belgium. Electro…. Hauptthemen laut MEDLINE: Isoflurane, Anesthetics, Inhalation, Anesthesia, Inhalation, Respiration, Artificial. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To compare isoflurane consumption and efficiency of an anaesthetic conserving device (ACD) and a vaporiser (VAP) in a circle breathing system during artificial ventilation. STUDY DESIGN: In vitro study. ANIMALS: None. METHODS: Isoflurane was delivered via VAP or ACD with tidal volumes (VTs) of 500 or 4000 mL, creating four setups: VAP500, VAP4000, ACD500 and ACD4000, each repeated four times. The ACD was positioned between an artificial lung and the Y-piece of the breathing circuit. For ACD4000, four ACDs were connected using a 3D-printed connector. Isoflurane delivery followed a predefined decision tree to achieve a concentration of 1.0% in the artificial lung. After reaching steady state, 400 breaths were recorded. Vapour concentrations were measured in the artificial lung (Clung) and scavenging hose (Cscav). Liquid isoflurane consumption and reflection efficiency (RE) were calculated. Data were analysed using generalised linear mixed models and Mann-Whitney U-tests in SPSS. Results are presented as means (95% confidence intervals). RESULTS: Liquid isoflurane consumption was lower with ACD500 than with VAP500 [1.2 (1.1-1.3) versus 5.4 mL (5.3-5.6); p = 0.021], and lower with ACD4000 than with VAP4000 [5.2 (4.4-6.0) versus 6.1 mL (5.7-6.4); p = 0.043]. RE was higher with ACD500 than with VAP500 [88.37 (88.17-88.56) versus 46.96% (46.59-47.32); p < 0.001], and higher with ACD4000 than with VAP4000 [93.69 (93.46-93.92) versus 92.61% (92.58-92.65); p < 0.001]. Cscav was lower with ACD500 than with VAP500 [0.0 (0.00-0.00) versus 0.29% (0.29-0.29); p < 0.001], and lower with ACD4000 than with VAP4000 [0.09 (0.07-0.10) versus 0.43% (0.42 - 0.44); p < 0.001]. CONCLUSION AND CLINICAL RELEVANCE: The ACD reduces isoflurane consumption and Cscav while improving RE at a fresh gas flow of 2 L minute-1 in circle breathing systems, indicating clinical and environmental benefits.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IsofluraneAnesthetics, InhalationAnesthesia, InhalationRespiration, ArtificialAnimalsNebulizers and Vaporizers

Stichwörter der Autor:innen

anaesthetic conserving devicecircle breathing systemconsumptionreflection efficiencyvaporiser

Substanzen

IsofluraneAnesthetics, Inhalation

Autor:innen und Institutionen

  • Department of Large Animal Surgery, Anaesthesia and Orthopaedics, Faculty of Veterinary Medicine, Ghent University, Merelbeke-Melle, Belgium. Electronic address: jana.flyps@ugent.be.
  • Department of Large Animal Surgery, Anaesthesia and Orthopaedics, Faculty of Veterinary Medicine, Ghent University, Merelbeke-Melle, Belgium.
  • Department of Anaesthesiology, Intensive Care, and Emergency Medicine, AZorg, Aalst, Belgium.
  • Department of Anaesthesiology, Intensive Care, and Emergency Medicine, AZorg, Aalst, Belgium; Department of Basic and Applied Medical Sciences, Ghent University, Ghent, Belgium; Department of Anaesthesiology, University…
  • Department of Anaesthesiology, Intensive Care Medicine and Pain Therapy, Saarland University Medical Centre and Saarland University Faculty of Medicine, Homburg, Germany.

Zitieren

APA

Flyps, J., Haspeslagh, M., Bouchez, S., Hendrickx, J. F. A., Meiser, A., & Schauvliege, S. (2026). Combining an anaesthetic conserving device with a circle breathing system to minimise isoflurane waste: an in vitro study. Veterinary Anaesthesia and Analgesia, 53(6), 101370. https://doi.org/10.1016/j.vaa.2026.101370

Vancouver

Flyps J, Haspeslagh M, Bouchez S, Hendrickx JFA, Meiser A, Schauvliege S. Combining an anaesthetic conserving device with a circle breathing system to minimise isoflurane waste: an in vitro study. Veterinary Anaesthesia and Analgesia. 2026;53(6):101370. doi:10.1016/j.vaa.2026.101370

BibTeX
@article{Flyps2026,
  author = {Flyps, Jana and Haspeslagh, Maarten and Bouchez, Stefaan and Hendrickx, Jan F A and Meiser, Andreas and Schauvliege, Stijn},
  title = {Combining an anaesthetic conserving device with a circle breathing system to minimise isoflurane waste: an in vitro study},
  journal = {Veterinary Anaesthesia and Analgesia},
  year = {2026},
  volume = {53},
  number = {6},
  pages = {101370},
  doi = {10.1016/j.vaa.2026.101370}
}
Kostenlos starten →