The use of a checklist reduces errors in equipment set-up by veterinary student anesthetists
Veterinary Anaesthesia and Analgesia · 2025
DOI: 10.1016/j.vaa.2025.05.003 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Veterinary Anaesthesia and Analgesia, 2025. Verfasst von Lydia Love und 2 weiteren Autor:innen. Beteiligte Einrichtung: NC State College of Veterinary Medicine, Department of Molecular Biomedical Sciences, Raleigh, NC, USA. Electronic address: lclove@ncsu.edu. Hauptthemen laut MEDLINE: Checklist, Education, Veterinary, Anesthesiology, Anesthesia. Die Arbeit nennt 28 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: To investigate the relative frequency of set-up errors documented before and after the introduction of an anesthesia equipment checklist in two successive veterinary classes. STUDY DESIGN: Pre- and post-intervention observational study. METHODS: In study year 1, our typical educational practices for training third year veterinary students in anesthesia equipment set-up and testing were followed (participant rate 96/96). In study year 2, a new third year class of students was introduced to and trained on the use of an anesthesia equipment checklist (participant rate 94/98). Data on errors in equipment set-up were recorded prospectively on a standardized collection sheet in a de-identified manner. Negative binomial regression models compared the overall count of errors per laboratory session and per possible error. Binary logistic regression models investigated the probability of each specific error occurring before and after introduction of the equipment checklist, as each specific error type could occur only once per equipment set-up. RESULTS: Checklist availability was the only variable with a significant effect on error. The relative number of errors per laboratory session was 88% less in the year after introduction of the checklist than the year prior, decreasing from an average of 0.066 errors per possible error (111 errors with 1691 opportunities for error) to 0.008 per possible error (15 errors with 1947 opportunities for error). The odds of making an airway supplies error from study year 1 to year 2 was reduced by 97.2%, decreasing from an occurrence in 16.2% of equipment set-ups to 0.8% of equipment set-ups. The odds of failure to open the adjustable pressure limiting valve decreased by 75.7%, from an occurrence in 5.9% of equipment set-ups to 1.5% of equipment set-ups. CONCLUSIONS AND CLINICAL RELEVANCE: Exposure to an anesthesia equipment checklist decreased but did not eliminate equipment set-up errors by student anesthetists.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- NC State College of Veterinary Medicine, Department of Molecular Biomedical Sciences, Raleigh, NC, USA. Electronic address: lclove@ncsu.edu.
- NC State College of Veterinary Medicine, Department of Molecular Biomedical Sciences, Raleigh, NC, USA.
- KR Love Quantitative Consulting and Collaboration, Athens, GA, USA.
Zitieren
APA
Love, L., Graham, L., & Love, K. (2025). The use of a checklist reduces errors in equipment set-up by veterinary student anesthetists. Veterinary Anaesthesia and Analgesia. https://doi.org/10.1016/j.vaa.2025.05.003
Vancouver
Love L, Graham L, Love K. The use of a checklist reduces errors in equipment set-up by veterinary student anesthetists. Veterinary Anaesthesia and Analgesia. 2025. doi:10.1016/j.vaa.2025.05.003
BibTeX
@article{Love2025,
author = {Love, Lydia and Graham, Lynelle and Love, Kim},
title = {The use of a checklist reduces errors in equipment set-up by veterinary student anesthetists},
journal = {Veterinary Anaesthesia and Analgesia},
year = {2025},
doi = {10.1016/j.vaa.2025.05.003}
}
EUVIMED