Computed tomography assessment of V-Gel Advanced supraglottic airway device placement in cats
Veterinary Anaesthesia and Analgesia · 2025
DOI: 10.1016/j.vaa.2025.01.014 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Anaesthesia and Analgesia, 2025. Verfasst von José M Gómez-Silvestre und 8 weiteren Autor:innen. Beteiligte Einrichtung: London Vet Specialists, London, UK. Electronic address: jmgomezs98@gmail.com. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Laryngeal Masks, Intubation, Intratracheal, Airway Management. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: To evaluate the placement of V-Gel Advanced supraglottic airway device (SGAD) in cats. STUDY DESIGN: Retrospective study. ANIMALS: A total of 75 client-owned cats with V-Gel Advanced (SGAD) undergoing computed tomography (CT) scans. METHODS: CT images of cats with SGADs in place and exhibiting normal capnogram waveforms were reviewed. The size, distance from the end of the SGAD connector to the incisors of the animal, closure of the anatomical area around the shoulders of the SGAD, perfect seal of the larynx, closure of the oesophagus, adequate size, presence of gas in the stomach, complications and other observations were recorded. Descriptive statistics and logistic regression were performed to assess the association of the factors studied with incorrect device placement. RESULTS: A total of 69 CTs were included in the study. The SGAD did not seal the area around the shoulders of the SGAD, the larynx or the oesophagus in 62.3% (43/69), 14.5% (10/69) and 72.5% (50/69) of the CTs, respectively. The device was slightly or very rotated in 26% (18/69) and 5.7% (4/69) of the CTs, respectively. The device was touching the epiglottis in 2.9% (2/69) of the CTs. The SGADs were positioned too caudally and too rostrally in 1.4% (1/69) and 2.9% (2/69) of the CTs, respectively. No association was found between factors studied and incorrect device placement. No complications were recorded. CONCLUSIONS AND CLINICAL RELEVANCE: Based on the results, normal capnography waveforms do not confirm the correct placement of the SGAD.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- London Vet Specialists, London, UK. Electronic address: jmgomezs98@gmail.com.
- London Vet Specialists, London, UK.
- Department of Animal Medicine and Surgery, Faculty of Veterinary Medicine, CEU Universities, Valencia, Spain.
- AniCura Indautxu Hospital Veterinario, Bilbao, Spain.
- Experimental Surgery Unit (ESU), Vall d'Hebron Institut de Recerca (VHIR), Hospital Universitari, Barcelona, Spain; Department of Animal Pathology, Faculty of Veterinary Medicine, University of Zaragoza, Zaragoza, Spain.
- AniCura Aitana Hospital Veterinario, Valencia, Spain.
Zitieren
APA
Gómez-Silvestre, J. M., García-Fernández, A., Redondo, J. I., Marti-Scharhausen, M. L. R., Cañón, A., Hernández, E. Z., Martínez, A., McCallum Neilson, D., & Viscasillas, J. (2025). Computed tomography assessment of V-Gel Advanced supraglottic airway device placement in cats. Veterinary Anaesthesia and Analgesia. https://doi.org/10.1016/j.vaa.2025.01.014
Vancouver
Gómez-Silvestre JM, García-Fernández A, Redondo JI, Marti-Scharhausen MLR, Cañón A, Hernández EZ, et al. Computed tomography assessment of V-Gel Advanced supraglottic airway device placement in cats. Veterinary Anaesthesia and Analgesia. 2025. doi:10.1016/j.vaa.2025.01.014
BibTeX
@article{GmezSilvestre2025,
author = {Gómez-Silvestre, José M and García-Fernández, Ana and Redondo, José Ignacio and Marti-Scharhausen, María de Los Reyes and Cañón, Ariel and Hernández, Eva Z and Martínez, Agustín and McCallum Neilson, David and Viscasillas, Jaime},
title = {Computed tomography assessment of V-Gel Advanced supraglottic airway device placement in cats},
journal = {Veterinary Anaesthesia and Analgesia},
year = {2025},
doi = {10.1016/j.vaa.2025.01.014}
}
EUVIMED