EUVIMEDEUVIMED entdecken
Evaluationsstudie

Evaluation of a novel, low-cost, 3D printed video laryngoscope with borescope in anesthetized Beagle dogs

Won-Gyun Son, Taehoon Sung, Donghwi Shin, Suehyung Rhee, Changhoon Nam, Minha Kim, Chailin Park, Jungha Lee, Junsoo Kim, Inhyung Lee

Veterinary Anaesthesia and Analgesia · 2024-05 · 51 (3) · 266-270

DOI: 10.1016/j.vaa.2024.03.006 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Veterinary Anaesthesia and Analgesia, 2024-05. Verfasst von Won-Gyun Son und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Seoul National University, Seoul, Republic of Korea. Electronic address: …. Hauptthemen laut MEDLINE: Laryngoscopes, Printing, Three-Dimensional, Intubation, Intratracheal. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 14 Literaturangaben. Gefördert von: Research Institute for Veterinary Science, College of Veterinary Medicine, Seoul National University, Ministry of Education, Science and Technology, National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To develop and evaluate a low-cost three-dimensional (3D)-printed video laryngoscope (VLVET) for use with a commercial borescope. STUDY DESIGN: Instrument development and pilot study. ANIMALS: A total of six adult male Beagle dogs. METHODS: The VLVET consisted of a laryngoscope handle and a Miller-type blade, and a detachable camera holder that attached to various locations along the blade. The laryngoscope and camera holder were 3D-printed using black polylactic acid filament. Dogs were premedicated with intravenous (IV) medetomidine (15 μg kg-1) and anesthesia induced with IV alfaxalone (1.5 mg kg-1). The VLVET, combined with a borescope, was used for laryngeal visualization and intubation. Performance was evaluated by comparing direct and video-assisted views in sternal recumbency. The borescope camera was sequentially positioned at 2, 4, 6, 8 and 10 cm from the blade tip (distanceLARYNX-CAM), which was placed on the epiglottis during intubation or laryngoscopy. At the 10 cm distanceLARYNX-CAM, laryngeal visualization was sequentially scored at inter-incisor gaps of 10, 8, 6, 4 and 2 cm. Laryngeal visualization scores (0-3 range, with 0 = obstructed and 3 = unobstructed views) were statistically analyzed using the Friedman's test. RESULTS: Under direct visualization, the 2 cm distanceLARYNX-CAM had a significantly lower score compared with all other distanceLARYNX-CAM (all p = 0.014) because the view was obstructed by the camera holder and borescope camera. With both direct and camera-assisted views, visualization scores were higher at inter-incisor gaps ≥ 4 cm compared with 2 cm (all p < 0.05). CONCLUSIONS AND CLINICAL RELEVANCE: During laryngoscopy and intubation, the VLVET and borescope facilitated both direct and video laryngoscopy at distanceLARYNX-CAM in Beagle dogs when inter-incisor gaps were ≥ 4 cm.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LaryngoscopesPrinting, Three-DimensionalIntubation, IntratrachealAnimalsDogsMaleVideo RecordingLaryngoscopyPilot ProjectsEquipment Design

Stichwörter der Autor:innen

caninedetachable camerainter-incisor gapintubationveterinary use

Autor:innen und Institutionen

  • Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Seoul National University, Seoul, Republic of Korea. Electronic address: carpeego@snu.ac.kr.
  • Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Seoul National University, Seoul, Republic of Korea.

Förderung

  • Research Institute for Veterinary Science, College of Veterinary Medicine, Seoul National University
  • Ministry of Education, Science and Technology
  • National Research Foundation of Korea
  • College of Veterinary Medicine, Seoul National University
  • Seoul National University

Zitieren

APA

Son, W. G., Sung, T., Shin, D., Rhee, S., Nam, C., Kim, M., Park, C., Lee, J., Kim, J., & Lee, I. (2024). Evaluation of a novel, low-cost, 3D printed video laryngoscope with borescope in anesthetized Beagle dogs. Veterinary Anaesthesia and Analgesia, 51(3), 266-270. https://doi.org/10.1016/j.vaa.2024.03.006

Vancouver

Son WG, Sung T, Shin D, Rhee S, Nam C, Kim M, et al. Evaluation of a novel, low-cost, 3D printed video laryngoscope with borescope in anesthetized Beagle dogs. Veterinary Anaesthesia and Analgesia. 2024;51(3):266-270. doi:10.1016/j.vaa.2024.03.006

BibTeX
@article{Son2024,
  author = {Son, Won-Gyun and Sung, Taehoon and Shin, Donghwi and Rhee, Suehyung and Nam, Changhoon and Kim, Minha and Park, Chailin and Lee, Jungha and Kim, Junsoo and Lee, Inhyung},
  title = {Evaluation of a novel, low-cost, 3D printed video laryngoscope with borescope in anesthetized Beagle dogs},
  journal = {Veterinary Anaesthesia and Analgesia},
  year = {2024},
  volume = {51},
  number = {3},
  pages = {266--270},
  doi = {10.1016/j.vaa.2024.03.006}
}
Kostenlos starten →