Ultrasound-guided and ‘blind’ sciatic nerve injection techniques: Comparison in rat cadavers
Veterinary Anaesthesia and Analgesia · 2024
DOI: 10.1016/j.vaa.2024.03.001 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Veterinary Anaesthesia and Analgesia, 2024. Verfasst von Douglas Castro und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Science, Auburn University College of Veterinary Medicine, Auburn, AL, USA. Electronic address: dzc0087@auburn.edu. Hauptthemen laut MEDLINE: Sciatic Nerve, Rats, Wistar, Ultrasonography, Interventional, Cadaver. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: College of Veterinary Medicine, Auburn University.
Abstract (Originalsprache)
OBJECTIVE: To compare the success rate and extent of sciatic nerve staining with a bupivacaine-dye solution using two injection techniques: 'blind' or ultrasound-guided approach. STUDY DESIGN: Prospective, experimental, randomized, cadaveric study. ANIMALS: Adult female Wistar rat cadavers [n = 24, mass 352 g (323-374)]. METHODS: Each sciatic nerve was randomly allocated to one of two groups: 'blind' (group B) or ultrasound-guided approach (group US) to injection. Following injection of bupivacaine-dye solution (0.1 mL), gross anatomical dissection was performed to visualize nerve staining, categorizing it as either positive or negative. The length of nerve staining was then measured and visual inspection conducted to identify potential nerve damage. Fisher's exact test was used to compare positive or negative nerve staining, and the Wilcoxon signed rank test used to compare the length of nerve staining between groups. RESULTS: In group B, the bupivacaine-dye solution stained 16/24 sciatic nerves (67% success). In group US, staining was successfully observed in all 24 nerves (100% success, p < 0.004). The length of nerve staining [median (interquartile range)] was 2 (2-3) mm in group B and 5 (4-6) mm in group US (p < 0.001). One sciatic nerve in group B had injectate distributed over 16 mm, suggestive of an intraneural injection. No signs of laceration or nerve damage were visible under 6× magnification in either group. CONCLUSIONS AND CLINICAL RELEVANCE: The ultrasound-guided approach for sciatic nerve injection demonstrated a higher success rate with superior injectate distribution when compared with the 'blind' approach. Ultrasound guidance is recommended over a 'blind' approach for sciatic nerve block in rats when possible.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Science, Auburn University College of Veterinary Medicine, Auburn, AL, USA. Electronic address: dzc0087@auburn.edu.
- Department of Clinical Science, Auburn University College of Veterinary Medicine, Auburn, AL, USA.
- Department of Comparative, Diagnostic & Population Medicine, University of Florida College of Veterinary Medicine, Gainesville, FL, USA.
Förderung
- College of Veterinary Medicine, Auburn University
Zitieren
APA
Castro, D., Ishihara, T., Hofmeister, E. H., Clark-Price, S., & Portela, D. A. (2024). Ultrasound-guided and ‘blind’ sciatic nerve injection techniques: Comparison in rat cadavers. Veterinary Anaesthesia and Analgesia. https://doi.org/10.1016/j.vaa.2024.03.001
Vancouver
Castro D, Ishihara T, Hofmeister EH, Clark-Price S, Portela DA. Ultrasound-guided and ‘blind’ sciatic nerve injection techniques: Comparison in rat cadavers. Veterinary Anaesthesia and Analgesia. 2024. doi:10.1016/j.vaa.2024.03.001
BibTeX
@article{Castro2024,
author = {Castro, Douglas and Ishihara, Toshitsugu and Hofmeister, Erik H and Clark-Price, Stuart and Portela, Diego A},
title = {Ultrasound-guided and ‘blind’ sciatic nerve injection techniques: Comparison in rat cadavers},
journal = {Veterinary Anaesthesia and Analgesia},
year = {2024},
doi = {10.1016/j.vaa.2024.03.001}
}
EUVIMED