EUVIMEDEUVIMED entdecken
Crossref

Testing controls demonstrates a high prevalence of non-HLA antibody positivity using pre-defined cutoff threshold in a bead-based assay using healthy control population

A Agrawal, M Zuccarelli, L L Wakefield, C A Schinstock, M J Gandhi, A J Bentall

Transplant Immunology · 2025

DOI: 10.1016/j.trim.2025.102265 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Transplant Immunology, 2025. Verfasst von A Agrawal und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Nephrology, Department of Medicine, McMaster University, Hamilton, Ontario, Canada; Division of Nephrology and Hypertension, Mayo Clinic,…. Hauptthemen laut MEDLINE: Isoantibodies. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Mayo Clinic.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Measuring non-HLA antibodies is a potentially important tool in assessing allograft dysfunction and needs to be correlated with clinical outcomes. Thus, determining the antibody distribution in healthy populations is important before correlating with clinical events. Using male blood donors, we selected a low immunological risk control cohort. METHODS: We analyzed samples from 92 male, non-transfused blood donors (donors) to assess the detection of antibodies in a normal population cohort using a non-HLA 33 antigen multiplex commercial assay. RESULTS: At manufacturer's suggested cutoff threshold (COT) of 75 % percentile, no donors had negative results and at 95 % percentile only three donors were negative across all 33 antigens. At each of the manufacturer's COT, the median (IQR) number positive antibody bead tests per donor was 13 (10-17), 11 (8-13) and 7 (5-10) at 75th, 85th and 95th percentile COT, respectively. There was poor correlation between manufacturer's COT and locally generated COT (range r = 0.520 to 0.595). The percentage of donors who had three or more positive antibody bead tests was: 98.9 % at 75th COT; 95.7 % at 85th COT and 93.5 % at 95th COT. CONCLUSIONS: Considering the high proportion of positive results in a low immunological risk cohort, application of non-HLA antibody measurement in a diseased cohort is not optimal, and difficult to correlate with clinical events. Further studies to determine normal detection rates are needed for assay COT and clinical application in diseases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IsoantibodiesHumansMaleBlood DonorsAdultHLA AntigensMiddle AgedPrevalenceCohort Studies

Stichwörter der Autor:innen

Non-HLA antibodiesSensitizationThreshold cut off

Substanzen

IsoantibodiesHLA Antigens

Autor:innen und Institutionen

  • Division of Nephrology, Department of Medicine, McMaster University, Hamilton, Ontario, Canada; Division of Nephrology and Hypertension, Mayo Clinic, Rochester, MN, United States of America; The William J von Liebig Cen…
  • Department of Transfusion Medicine, Mayo Clinic, Rochester, MN, United States of America.
  • Division of Nephrology and Hypertension, Mayo Clinic, Rochester, MN, United States of America; The William J von Liebig Center for Transplantation and Clinical Regeneration, Mayo Clinic, Rochester, MN, United States of…

Förderung

  • Mayo Clinic

Zitieren

APA

Agrawal, A., Zuccarelli, M., Wakefield, L. L., Schinstock, C. A., Gandhi, M. J., & Bentall, A. J. (2025). Testing controls demonstrates a high prevalence of non-HLA antibody positivity using pre-defined cutoff threshold in a bead-based assay using healthy control population. Transplant Immunology. https://doi.org/10.1016/j.trim.2025.102265

Vancouver

Agrawal A, Zuccarelli M, Wakefield LL, Schinstock CA, Gandhi MJ, Bentall AJ. Testing controls demonstrates a high prevalence of non-HLA antibody positivity using pre-defined cutoff threshold in a bead-based assay using healthy control population. Transplant Immunology. 2025. doi:10.1016/j.trim.2025.102265

BibTeX
@article{Agrawal2025,
  author = {Agrawal, A and Zuccarelli, M and Wakefield, L L and Schinstock, C A and Gandhi, M J and Bentall, A J},
  title = {Testing controls demonstrates a high prevalence of non-HLA antibody positivity using pre-defined cutoff threshold in a bead-based assay using healthy control population},
  journal = {Transplant Immunology},
  year = {2025},
  doi = {10.1016/j.trim.2025.102265}
}
Kostenlos starten →