Diagnostic Value of Color Doppler Ultrasound in Transplanted Renal Artery Stenosis
Transplantation Proceedings · 2025
DOI: 10.1016/j.transproceed.2025.03.009 ↗Kurz gefasst
Fachartikel in der Zeitschrift Transplantation Proceedings, 2025. Verfasst von Yu Huimin und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Tianjin First Central Hospital, Tianjin, China. Hauptthemen laut MEDLINE: Renal Artery Obstruction, Ultrasonography, Doppler, Color, Kidney Transplantation, Renal Artery. Die Arbeit nennt 18 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Tianjin Municipality.
Abstract (Originalsprache)
OBJECTIVE: This study is to investigate the diagnostic features and efficacy of ultrasonography in transplanted renal artery stenosis (TRAS). METHODS: We collected data from 20 patients diagnosed with TRAS via digital subtraction angiography (DSA) between July 2016 and January 2024 at the First Central Hospital of Tianjin. Additionally, we randomly selected 30 patients with normal blood flow and stable renal function following renal transplantation to serve as the control group. We utilized color Doppler ultrasound to assess various blood flow parameters, including the peak systolic velocity (PSV1) and diastolic velocity (EDV1) of the interlobar artery, the resistance index (RI) of the interlobar artery, and the systolic acceleration time (SAT) of the interlobar artery. We also measured the velocity of the interlobar vein (V), the peak systolic velocity (PSV2) and diastolic velocity (EDV2) at the stenosis site of the transplanted renal artery, the resistance index at the stenosis site, and the diameter of the stenosis of the transplanted renal artery (D). Concurrently, we recorded creatinine (Cr) levels within 24 hours. We compared the color Doppler ultrasound blood flow parameters of the TRAS group before interventional therapy with those of the control group and constructed ROC curves to determine the area and critical values under each parameter curve. We also selected cases post-stent implantation to compare the differences in color Doppler blood flow parameters before and after treatment, thereby analyzing the characteristics of hemodynamic changes. RESULTS: PSV1, EDV1, interlobar RI, stenosis RI in the TRAS group were significantly lower than those in the control group (t = 6.976, P = .000; T = 3.748, P = .000; Z = -4.115, P = .000; T = 6.537, P = .000; Z = -4.979, P = .000). Conversely, the PSV2, EDV2, SAT, and Cr levels in the TRAS group were higher than those in the control group (Z = -5.942, P = .000; Z = -5.735, P = .000; Z = -5.897, P = .000; Z = -5.941, P = .000). ROC curve analysis revealed that PSV2 exhibited the highest sensitivity and specificity for diagnosing TRAS, both at 100%, with a critical value of 205 cm/s. This was followed by the interlobar artery SAT, which showed a sensitivity of 95% and a specificity of 100%, with a critical value of 0.08 s. Additionally, after stent placement, the PSV1, EDV1, interlobar RI, and stenosis RI were significantly higher than before stent placement (Z = -5.17, P = .000; Z = -2.695, P = .019; T = 3.841, P = .002; Z = -4.974, P = .000). In contrast, the PSV2, EDV2, and Cr levels after stent placement were lower than those prior to the procedure (t = 7.518, P = .000; T = 5.837, P = .000; Z = 11.567, P = .000). CONCLUSION: Color doppler ultrasound is a non-invasive, effective, simple, and rapid imaging modality that can serve as the first choice for the initial diagnosis of TRAS following renal transplantation and for postoperative follow-up. The peak systolic velocity at stenosis and the systolic acceleration time of the interlobar artery are particularly effective in diagnosing TRAS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Ultrasound, Tianjin First Central Hospital, Tianjin, China.
- Department of Ultrasound, Tianjin First Central Hospital, Tianjin, China. Electronic address: doctortang2002@aliyun.com.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Tianjin Municipality
Zitieren
APA
Huimin, Y., Weina, K., Ningning, N., Hongtao, W., Guoying, Z., Xiaoye, H., Jing, W., & Ying, T. (2025). Diagnostic Value of Color Doppler Ultrasound in Transplanted Renal Artery Stenosis. Transplantation Proceedings. https://doi.org/10.1016/j.transproceed.2025.03.009
Vancouver
Huimin Y, Weina K, Ningning N, Hongtao W, Guoying Z, Xiaoye H, et al. Diagnostic Value of Color Doppler Ultrasound in Transplanted Renal Artery Stenosis. Transplantation Proceedings. 2025. doi:10.1016/j.transproceed.2025.03.009
BibTeX
@article{Huimin2025,
author = {Huimin, Yu and Weina, Kong and Ningning, Niu and Hongtao, Wu and Guoying, Zhang and Xiaoye, Hao and Jing, Wang and Ying, Tang},
title = {Diagnostic Value of Color Doppler Ultrasound in Transplanted Renal Artery Stenosis},
journal = {Transplantation Proceedings},
year = {2025},
doi = {10.1016/j.transproceed.2025.03.009}
}
EUVIMED