EUVIMEDEUVIMED entdecken
Crossref

Discrepancy Between Pulmonary Artery Catheter and Co-Oximeter Value of Mixed Venous Oxygen Saturation After Graft Reperfusion During Living Donor Liver Transplantation

Yeonji Noh, Jeayoun Kim, Sooyeon Lee, Jisun Choi, Gaab Soo Kim

Transplantation Proceedings · 2024

DOI: 10.1016/j.transproceed.2024.11.015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Transplantation Proceedings, 2024. Verfasst von Yeonji Noh und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Liver Transplantation, Living Donors, Oximetry, Catheterization, Swan-Ganz. Die Arbeit nennt 13 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Monitoring tissue oxygenation is critical in liver recipients. The pulmonary artery catheter (PAC) provides continuous monitoring of mixed venous oxygen saturation (SvO2) using fiberoptic reflectance spectrophotometry. Despite the need for in vivo calibration during liver transplantation, recalibration guidelines are absent, and we frequently observed a significant discrepancy between PAC and reference co-oximeter SvO2 values after graft reperfusion. This study aimed to assess the incidence and risk factors of a significant discrepancy after reperfusion during living donor liver transplantation. METHODS: This retrospective study included 54 recipients who underwent living donor liver transplantation at our institution between October 2021 and April 2022. A PAC was inserted, and in vivo calibration was conducted using the co-oximeter SvO2 value. We defined a significant discrepancy as a drift was ≥ 3% at 1 hour after reperfusion. Logistic regression analysis was performed to determine the association between perioperative variables and the risk of significant discrepancy. RESULTS: PAC SvO2 was higher than co-oximeter SvO2 in 51 recipients. A significant discrepancy was observed in 37 recipients (68.5%). The risk of significant discrepancy decreased with a high preoperative hemoglobin concentration (odds ratio [OR] = 0.65 [0.47-0.91], P = .011) and a high arterial oxygen partial pressure (PaO2) at 1 hour after reperfusion (OR = 0.96 [0.94-0.99], P = .004) but increased with a high baseline co-oximeter SvO2 value (OR = 1.29 [1.05-1.59], P = .015). CONCLUSIONS: PAC SvO2 significantly drifted from the reference co-oximeter value in over two-thirds of recipients after reperfusion. Therefore, in vivo recalibration is required for the reliable measurement of PAC SvO2 during living donor liver transplantation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Liver TransplantationLiving DonorsOximetryCatheterization, Swan-GanzOxygen SaturationHumansRetrospective StudiesMaleFemaleMiddle AgedAdultReperfusionOxygenPulmonary ArteryMonitoring, Intraoperative

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
  • Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea. Electronic address: gskim@skku.edu.

Zitieren

APA

Noh, Y., Kim, J., Lee, S., Choi, J., & Kim, G. S. (2024). Discrepancy Between Pulmonary Artery Catheter and Co-Oximeter Value of Mixed Venous Oxygen Saturation After Graft Reperfusion During Living Donor Liver Transplantation. Transplantation Proceedings. https://doi.org/10.1016/j.transproceed.2024.11.015

Vancouver

Noh Y, Kim J, Lee S, Choi J, Kim GS. Discrepancy Between Pulmonary Artery Catheter and Co-Oximeter Value of Mixed Venous Oxygen Saturation After Graft Reperfusion During Living Donor Liver Transplantation. Transplantation Proceedings. 2024. doi:10.1016/j.transproceed.2024.11.015

BibTeX
@article{Noh2024,
  author = {Noh, Yeonji and Kim, Jeayoun and Lee, Sooyeon and Choi, Jisun and Kim, Gaab Soo},
  title = {Discrepancy Between Pulmonary Artery Catheter and Co-Oximeter Value of Mixed Venous Oxygen Saturation After Graft Reperfusion During Living Donor Liver Transplantation},
  journal = {Transplantation Proceedings},
  year = {2024},
  doi = {10.1016/j.transproceed.2024.11.015}
}
Kostenlos starten →