Fachartikel in der Zeitschrift Translational Dental Research, 2025. Verfasst von Hefei Bai und 6 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Beijing Natural Science Foundation.
Abstract (Originalsprache)
Objective
To establish a design and fabrication method for a rigid constraint guiding template for preparing rest seats for removable partial dentures (RPDs) and to verify the feasibility and accuracy of template-guided preparation in vitro .
Methods
Twenty identical Type IV gypsum casts of Kennedy Class II mandibular partially edentulous arch (missing teeth #36, #37, #45 and #46) were replicated and evenly divided into two groups: the template-guided group and the freehand group. Virtual preparation of rest seats on three abutment teeth were performed, and two rigid constraint preparation templates were designed and three dimensional (3D) printed using titanium alloy. A trained prosthodontist used the template-assisted method and the freehand preparation method to prepare rest seats for both groups respectively. The root mean square errors (RMSE) of 3D trueness and 3D precision of prepared rest seats in both groups were analyzed using the 3D compare method. Finally, a single-blind subjective scoring and quantitative analysis of the rest seat preparation were conducted by another trained prosthodontist.
Results
The positioning accuracy of the rigid constraint templates for rest seat preparation was (249 (79.4) μm). The 3D accuracy (138.09 ± 30.33 μm) and 3D precision (100.20 (79.60) μm) of the rest seat preparation using the rigid constraint template were superior to the 3D accuracy (253.44 ± 38.84 μm) and 3D precision (217.70 (121.25) μm) of the freehand preparation ( P < 0.001). The scoring results for the quality of the rest seat preparation indicated that the morphology and position of the rest seats prepared using the template were significantly better than those prepared by the freehand method ( P < 0.05).
Conclusions
The rigid constraint template accurately guided the diamond bur to prepare rest seats that meet clinical requirements on multiple abutment teeth. Compared to freehand preparation by a trained prosthodontist, the template-guided preparation resulted in better shape and position of the rest seats, significantly reducing the dependency on the experience and skills of the clinicians. Clinical significance The rigid constraint metal template offers a new digital auxiliary method for achieving stable and high-quality rest seat preparation for RPDs.
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- Beijing Natural Science Foundation
- Research Foundation of Peking University School and Hospital of Stomatology
- Peking University
- Chinese Academy of Medical Sciences
- Non-profit Central Research Institute Fund of Chinese Academy of Medical Sciences
- Natural Science Foundation of Beijing Municipality
Zitieren
APA
Bai, H., Ye, H., Chen, H., Jiang, D., Zhou, Y., Tian, S., & Sun, Y. (2025). Accuracy of rest seat prepared by rigid constraint template for removable partial denture: An in vitro study. Translational Dental Research. https://doi.org/10.1016/j.tdr.2025.100033
Vancouver
Bai H, Ye H, Chen H, Jiang D, Zhou Y, Tian S, et al. Accuracy of rest seat prepared by rigid constraint template for removable partial denture: An in vitro study. Translational Dental Research. 2025. doi:10.1016/j.tdr.2025.100033
BibTeX
@article{Bai2025,
author = {Bai, Hefei and Ye, Hongqiang and Chen, Hu and Jiang, Dongyao and Zhou, Yongsheng and Tian, Sukun and Sun, Yuchun},
title = {Accuracy of rest seat prepared by rigid constraint template for removable partial denture: An in vitro study},
journal = {Translational Dental Research},
year = {2025},
doi = {10.1016/j.tdr.2025.100033}
}
EUVIMED