Stimuli-responsive (switchable) deep eutectic solvents in microextraction: Status, challenges and prospects in food safety and environmental analysis
Talanta · 2027-04 · 314 · 130863
DOI: 10.1016/j.talanta.2026.130863 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Talanta, 2027-04. Verfasst von Huma Javeria und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Toxicology, Pusat Kanser Tun Abdullah Ahmad Badawi (PKTAAB), Universiti Sains Malaysia, Bertam Kepala Batas, 13200, Pulau Pinang, Malay…. Hauptthemen laut MEDLINE: Liquid Phase Microextraction, Deep Eutectic Solvents, Food Safety, Environmental Monitoring. Die Arbeit nennt 85 Literaturangaben. Gefördert von: Kurita Water and Environment Foundation, Malaysia Ministry of Higher Education, Universiti Sains Malaysia.
Abstract (Originalsprache)
Deep eutectic solvents (DESs) have attracted considerable attention as green extraction solvents; however, their application in microextraction is often limited by difficult phase separation, poor recyclability, and the need for additional separation steps. Stimuli-responsive or switchable deep eutectic solvents (S-DES) overcome these limitations through reversible hydrophilic-hydrophobic transitions triggered by external stimuli such as CO2/N2, pH, or temperature, enabling efficient extraction, rapid phase separation, and solvent reuse. This review critically examines the current status, challenges, and prospects of S-DES in microextraction for food safety and environmental analysis. The design principles, classification, and switching mechanisms of CO2/N2-, pH-, temperature-, magnetic-, photo-, and electro-responsive S-DES are discussed and critically assessed, together with the molecular interactions governing analyte extraction. Recent applications in liquid-phase microextraction for pesticides, antibiotics, pharmaceuticals, mycotoxins, heavy metals, and emerging contaminants are systematically evaluated. The role of computational tools, including COSMO-RS, density functional theory, molecular dynamics simulations, and machine learning, in understanding extraction mechanisms and guiding solvent design is also highlighted. Current challenges include limited validation in complex matrices, a lack of standardized switching protocols, and the underutilization of temperature-responsive systems. Future research directions focusing on temperature-responsive extraction platforms, multi-class contaminant extraction, and AI-assisted solvent design are discussed. S-DES show strong potential for developing greener, simpler, and more efficient microextraction methods for food safety and environmental monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Toxicology, Pusat Kanser Tun Abdullah Ahmad Badawi (PKTAAB), Universiti Sains Malaysia, Bertam Kepala Batas, 13200, Pulau Pinang, Malaysia.
- Department of Toxicology, Pusat Kanser Tun Abdullah Ahmad Badawi (PKTAAB), Universiti Sains Malaysia, Bertam Kepala Batas, 13200, Pulau Pinang, Malaysia. Electronic address: noorfatimah@usm.my.
- School of Chemistry and Environment, Faculty of Applied Sciences, Universiti Teknologi MARA, Cawangan Negeri Sembilan, Kampus Kuala Pilah, Kuala Pilah, 72000, Negeri Sembilan, Malaysia.
- Laboratory of Nanomaterials Processing and Technology, Institute of Nanoscience and Nanotechnology and Department of Chemistry, Faculty of Science, Universiti Putra Malaysia, Serdang, Selangor, 43400, Malaysia.
- Université de Lorraine, CNRS, LCPME, F-54000, Nancy, France.
- Department of Chemistry, University of British Columbia, Vancouver, V6T 1Z1, BC, Canada.
Förderung
- Kurita Water and Environment Foundation
- Malaysia Ministry of Higher Education
- Universiti Sains Malaysia
Zitieren
APA
Javeria, H., Yahaya, N., Mohamed, A. H., Kamaruzaman, S., Mohamad Zain, N. N., Herzog, G., Chen, D., & Hong, L. S. (2027). Stimuli-responsive (switchable) deep eutectic solvents in microextraction: Status, challenges and prospects in food safety and environmental analysis. Talanta, 314, 130863. https://doi.org/10.1016/j.talanta.2026.130863
Vancouver
Javeria H, Yahaya N, Mohamed AH, Kamaruzaman S, Mohamad Zain NN, Herzog G, et al. Stimuli-responsive (switchable) deep eutectic solvents in microextraction: Status, challenges and prospects in food safety and environmental analysis. Talanta. 2027;314:130863. doi:10.1016/j.talanta.2026.130863
BibTeX
@article{Javeria2027,
author = {Javeria, Huma and Yahaya, Noorfatimah and Mohamed, Ahmad Husaini and Kamaruzaman, Sazlinda and Mohamad Zain, Nur Nadhirah and Herzog, Grégoire and Chen, David and Hong, Lim Sheh},
title = {Stimuli-responsive (switchable) deep eutectic solvents in microextraction: Status, challenges and prospects in food safety and environmental analysis},
journal = {Talanta},
year = {2027},
volume = {314},
pages = {130863},
doi = {10.1016/j.talanta.2026.130863}
}
EUVIMED