EUVIMEDEUVIMED entdecken
Crossref

Aluminum-copper layered double hydroxide-enabled electrochemiluminescence-multicolor dual-mode biosensor for heparin-binding protein detection in sepsis diagnosis

Zhenjie Zheng, Mengqi Ma, Liang Wang, Da Huang, Yue Lin, Jian Wang, Cuiying Lin, Zhenyu Lin, Fang Luo

Talanta · 2026

DOI: 10.1016/j.talanta.2026.129458 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Talanta, 2026. Verfasst von Zhenjie Zheng und 8 weiteren Autor:innen. Beteiligte Einrichtung: College of Biological Science and Engineering, Fuzhou University, Fuzhou, Fujian, 350116, China; Ministry of Education Key Laboratory of Analytical S…. Hauptthemen laut MEDLINE: Biosensing Techniques, Sepsis, Copper, Carrier Proteins. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: Natural Science Foundation of Fujian Province, Fuzhou University, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sepsis is a critical condition associated with substantial mortality, thus driving a pressing demand for rapid diagnostic approaches ranging from simple, readily deployable point-of-care testing (POCT) to highly sensitive laboratory-based detection methods. Heparin-binding protein (HBP), a neutrophil-derived protein, rises earlier and correlates more closely with disease severity than conventional biomarkers including procalcitonin and C-reactive protein, making it a promising biomarker for timely sepsis detection. To simultaneously meet these needs, we established a dual-mode biosensor that combines electrochemiluminescence (ECL) and multicolor for highly sensitive analysis of HBP. The sensing platform is constructed from an aluminum-copper layered double hydroxide (AlCu-LDH) scaffold conjugated with an HBP-specific aptamer and complementary DNA immobilized on magnetic beads (MBs). In the absence of HBP, the assembled AlCu-LDH-MBs probe suppresses ECL emission through ferrocene-mediated quenching while catalyzing efficient TMB oxidation to produce a strong multicolor response. Upon HBP binding, conformational switching induces probe disassembly, releasing AlCu-LDH and ferrocene from the duplex, thereby restoring ECL output while simultaneously attenuating the multicolor signal. Under optimized conditions, the biosensor achieved an ultralow detection limit of 0.023 pM in ECL mode with a linear range of 0.10 pM-10 nM, whereas the multicolor mode showed a detection limit of 0.43 nM and exhibited linearity across 0.50-10 nM, accompanied by an intuitive multicolor transition from gray to purple. Notably, this strategy avoids tedious electrode surface modification and relies on magnetic separation to regulate signal generation, thereby simplifying operation while offering a sensitive and practical tool for early sepsis diagnosis that bridges laboratory-grade analysis with instrument-free POCT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesSepsisCopperCarrier ProteinsHumansAluminumHydroxidesLuminescent MeasurementsElectrochemical TechniquesAptamers, NucleotideBiomarkersBlood ProteinsAntimicrobial Cationic Peptides

Stichwörter der Autor:innen

Dual-mode biosensorElectrochemiluminescenceHeparin-binding proteinMulticolorSepsis

Substanzen

CopperAluminumHydroxidesAZU1 protein, humanCarrier ProteinsAptamers, NucleotideBiomarkersBlood ProteinsAntimicrobial Cationic Peptides

Autor:innen und Institutionen

  • College of Biological Science and Engineering, Fuzhou University, Fuzhou, Fujian, 350116, China; Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Key Laboratory of Analysis…
  • College of Biological Science and Engineering, Fuzhou University, Fuzhou, Fujian, 350116, China.
  • Global Centre for Environmental Remediation, College of Engineering, Science and Environment, University of Newcastle, Callaghan, New South Wales, 2308, Australia.
  • Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Key Laboratory of Analysis and Testing Technology for Food Safety and Health, College of Chemistry, Fuzhou University, 2 Xue…

Förderung

  • Natural Science Foundation of Fujian Province
  • Fuzhou University
  • National Natural Science Foundation of China

Zitieren

APA

Zheng, Z., Ma, M., Wang, L., Huang, D., Lin, Y., Wang, J., Lin, C., Lin, Z., & Luo, F. (2026). Aluminum-copper layered double hydroxide-enabled electrochemiluminescence-multicolor dual-mode biosensor for heparin-binding protein detection in sepsis diagnosis. Talanta. https://doi.org/10.1016/j.talanta.2026.129458

Vancouver

Zheng Z, Ma M, Wang L, Huang D, Lin Y, Wang J, et al. Aluminum-copper layered double hydroxide-enabled electrochemiluminescence-multicolor dual-mode biosensor for heparin-binding protein detection in sepsis diagnosis. Talanta. 2026. doi:10.1016/j.talanta.2026.129458

BibTeX
@article{Zheng2026,
  author = {Zheng, Zhenjie and Ma, Mengqi and Wang, Liang and Huang, Da and Lin, Yue and Wang, Jian and Lin, Cuiying and Lin, Zhenyu and Luo, Fang},
  title = {Aluminum-copper layered double hydroxide-enabled electrochemiluminescence-multicolor dual-mode biosensor for heparin-binding protein detection in sepsis diagnosis},
  journal = {Talanta},
  year = {2026},
  doi = {10.1016/j.talanta.2026.129458}
}
Kostenlos starten →