EUVIMEDEUVIMED entdecken
Crossref

An electrochemical 3-hydroxybutyrate biosensor using phenazine-based electron mediators

Jindian Liu, Tianbao Yang, Xue Li, Ye Zhang, Keke Dong, Qikang Huang, Yangfei Gan, Wenjie Fan, Yu Qin, Yueling Liu, Jinxu Gao

Talanta · 2026

DOI: 10.1016/j.talanta.2026.129408 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Talanta, 2026. Verfasst von Jindian Liu und 10 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Bioreactor Engineering, School of Biotechnology, East China University of Science and Technology, Shanghai, 200237, China; Ea…. Hauptthemen laut MEDLINE: 3-Hydroxybutyric Acid, Biosensing Techniques, Electrochemical Techniques, Phenazines. Die Arbeit nennt 70 Literaturangaben. Gefördert von: Key Technologies Research and Development Program, Graduate Research and Innovation Projects of Jiangsu Province, State Key Laboratory of Bioreactor Engineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate quantification of 3-hydroxybutyrate (3-HB) is essential for the diagnosis and management of diabetic ketoacidosis and related metabolic disorders. As the predominant ketone body during ketosis, blood 3-HB provides a more reliable clinical indicator than conventional ketone assays, motivating the development of rapid point-of-care detection platforms. Herein, we report an electrochemical biosensor that integrates phenazine-based redox mediators with NAD-dependent 3-hydroxybutyrate dehydrogenase (HBDH) for the sensitive and selective detection of 3-HB. Three phenazine derivatives were systematically evaluated using molecular docking, solubility assessment and electrochemical characterization. Among them, compound 3 exhibited superior aqueous solubility, high electrochemical stability, and a strong linear response (R2 = 0.9993) across a 3-HB concentration range of 0.05-14 mM within 20 s. When incorporated into a screen-printed test strip, the biosensor demonstrated consistent performance after five days of incubation at 60 °C with minimal signal drift. Interference testing confirmed less than ±15 % deviation in the presence of clinically relevant concentrations of glucose, uric acid, ascorbic acid, lactic acid, and creatinine. These results establish compound 3 as a highly effective electron mediator, supporting its potential application in reliable point-of-care and clinical 3-HB monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

3-Hydroxybutyric AcidBiosensing TechniquesElectrochemical TechniquesPhenazinesHumansHydroxybutyrate DehydrogenaseMolecular Docking SimulationDiabetic Ketoacidosis

Stichwörter der Autor:innen

3-HydroxybutyrateDiabetic ketoacidosisElectrochemical biosensorNAD-Dependent HBDHPhenazine mediatorPoint-of-care testing

Substanzen

3-Hydroxybutyric AcidPhenazinesHydroxybutyrate Dehydrogenase

Autor:innen und Institutionen

  • State Key Laboratory of Bioreactor Engineering, School of Biotechnology, East China University of Science and Technology, Shanghai, 200237, China; Eaglenos Sciences, Inc., 73 Tanmi Road, BLDG B2-2, Nanjing, 210044, Jian…
  • PharmaBlock Sciences, Inc., 81 Huasheng Road, Jiangbei New Area, Nanjing, 210032, Jiangsu, China.
  • Eaglenos Sciences, Inc., 73 Tanmi Road, BLDG B2-2, Nanjing, 210044, Jiangsu, China. Electronic address: qin_yu@eaglenos.com.
  • State Key Laboratory of Bioreactor Engineering, School of Biotechnology, East China University of Science and Technology, Shanghai, 200237, China. Electronic address: yuelingliu@ecust.edu.cn.
  • Eaglenos Sciences, Inc., 73 Tanmi Road, BLDG B2-2, Nanjing, 210044, Jiangsu, China. Electronic address: gao_jinxu@eaglenos.com.

Förderung

  • Key Technologies Research and Development Program
  • Graduate Research and Innovation Projects of Jiangsu Province
  • State Key Laboratory of Bioreactor Engineering
  • National Natural Science Foundation of China

Zitieren

APA

Liu, J., Yang, T., Li, X., Zhang, Y., Dong, K., Huang, Q., Gan, Y., Fan, W., Qin, Y., Liu, Y., & Gao, J. (2026). An electrochemical 3-hydroxybutyrate biosensor using phenazine-based electron mediators. Talanta. https://doi.org/10.1016/j.talanta.2026.129408

Vancouver

Liu J, Yang T, Li X, Zhang Y, Dong K, Huang Q, et al. An electrochemical 3-hydroxybutyrate biosensor using phenazine-based electron mediators. Talanta. 2026. doi:10.1016/j.talanta.2026.129408

BibTeX
@article{Liu2026,
  author = {Liu, Jindian and Yang, Tianbao and Li, Xue and Zhang, Ye and Dong, Keke and Huang, Qikang and Gan, Yangfei and Fan, Wenjie and Qin, Yu and Liu, Yueling and Gao, Jinxu},
  title = {An electrochemical 3-hydroxybutyrate biosensor using phenazine-based electron mediators},
  journal = {Talanta},
  year = {2026},
  doi = {10.1016/j.talanta.2026.129408}
}
Kostenlos starten →