PVDF/M5AH@UiO-66-NH2 composite membrane: Efficient separation of breath acetone/isoprene and highly sensitive detection via CRDS
Talanta · 2026-05 · 302 · 129407
DOI: 10.1016/j.talanta.2026.129407 ↗Kurz gefasst
Fachartikel in der Zeitschrift Talanta, 2026-05. Verfasst von Fengyun Su und 8 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Advanced Separation Membrane Materials, School of Materials Science and Engineering, Tiangong University, Tianjin, 300387, Ch…. Hauptthemen laut MEDLINE: Hemiterpenes, Acetone, Pentanes, Butadienes. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Chinese Academy of Medical Sciences, National Natural Science Foundation of China.
Abstract (Originalsprache)
Cavity ringdown spectroscopy (CRDS) is a sensitive laser absorption technique that can detect volatile organic compounds (VOCs) in human breath. Notably, CRDS exhibits a distinct absorbance for exhaled isoprene, a potential biomarker for lung cancer, at a wavelength of 226.56 nm. However, the presence of acetone in breath samples interferes with the accurate measurements of isoprene by CRDS. To address this issue, we developed a novel PVDF/M5AH@UiO-66-NH2 composite membrane for the ultra-trace separation of isoprene and acetone at ppbv levels (volume concentration of 10-9). As verified by PTR-TOF-MS, the optimal modified membrane, PVDF/M5AH@UiO-66-NH20.5, effectively reduced the acetone concentration by approximately 89.2 % ± 2.7 %, while minimally affecting the isoprene concentration (8.9 % ± 4.0 %). Analysis of breath samples from 76 lung cancer patients and 92 healthy controls, using both PTR-TOF-MS and CRDS techniques, revealed that the exhaled isoprene levels in healthy controls (238.7 ± 106.2 ppbv) were higher than those in patients (169.0 ± 52.6 ppbv). After membrane separation, CRDS showed a significant decrease in isoprene concentration among lung cancer patients, from 294.8 ± 65.4 ppbv to 191.1 ± 56.0 ppbv, thereby improving diagnostic accuracy. Moreover, the receiver operating characteristic (ROC) curve analysis demonstrates the enhanced diagnostic potential of exhaled isoprene after membrane separation, highlighting its potential in biomarker validation, sensitive and accurate clinical diagnosis, and long-term monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Advanced Separation Membrane Materials, School of Materials Science and Engineering, Tiangong University, Tianjin, 300387, China; Cangzhou Institute of Tiangong University, Cangzhou, 061000, Chin…
- Ocean University of China, Laoshan Campus 238 Songling Road, Laoshan District, Qingdao, 266100, Shandong, China.
- Institute of Biomedical Engineering, Chinese Academy of Medical Science & Peking Union Medical College, Tianjin, 300192, China. Electronic address: sunmx@bme.cams.cn.
- College of Chemistry and Pharmaceutical Sciences, Qingdao Agricultural University, Qingdao, 266109, China. Electronic address: qzliu@qau.edu.cn.
- Department of Respiratory and Critical Medicine, Tianjin Chest Hospital, Tianjin, 300222, China.
Förderung
- Chinese Academy of Medical Sciences
- National Natural Science Foundation of China
Zitieren
APA
Su, F., Zhang, B., Liu, Q., Sun, M., Liu, Q., Fu, W., Yin, Y., Zhao, Y., & Chen, L. (2026). PVDF/M5AH@UiO-66-NH2 composite membrane: Efficient separation of breath acetone/isoprene and highly sensitive detection via CRDS. Talanta, 302, 129407. https://doi.org/10.1016/j.talanta.2026.129407
Vancouver
Su F, Zhang B, Liu Q, Sun M, Liu Q, Fu W, et al. PVDF/M5AH@UiO-66-NH2 composite membrane: Efficient separation of breath acetone/isoprene and highly sensitive detection via CRDS. Talanta. 2026;302:129407. doi:10.1016/j.talanta.2026.129407
BibTeX
@article{Su2026,
author = {Su, Fengyun and Zhang, Bojun and Liu, Qianqian and Sun, Meixiu and Liu, Qingzhi and Fu, Weigui and Yin, Yan and Zhao, Yiping and Chen, Li},
title = {PVDF/M5AH@UiO-66-NH2 composite membrane: Efficient separation of breath acetone/isoprene and highly sensitive detection via CRDS},
journal = {Talanta},
year = {2026},
volume = {302},
pages = {129407},
doi = {10.1016/j.talanta.2026.129407}
}
EUVIMED