Fachartikel in der Zeitschrift Talanta, 2026. Verfasst von Ting Guo und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Wuhan University, Wuhan, 430072, China. Hauptthemen laut MEDLINE: Aflatoxin B1, Metal Nanoparticles, Mass Spectrometry. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Ministry of Education of the People's Republic of China, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Single particle (SP)-ICP-MS with elemental labeling is a new technique for quantification analysis of biospecies with good sensitivity, high specificity and strong anti-matrix interference ability, but barely applied for detection of toxins. Herein, we developed a homogeneous SP-ICP-MS assay for detection of aflatoxin B1 (AFB1) based on aptamer recognition, multicomponent nucleic acid enzyme (MNAzyme) amplification, and AuNP elemental labeling probes. In the absence of AFB1, the Linker DNA is complementary to the two AuNP probes, which will form large assembly AuNP aggregates. In the presence of AFB1, it specifically bonds to the aptamer to release the primer from aptamer-primer hybridized chains, which activates the MNAzyme system to cleave the Linker, causing the formed AuNP aggregates reduced. The AuNP aggregates in the solution are subjected to SP-ICP-MS detection by monitoring the Au pulses signals, and sensitive detection of AFB1 can be achieved via correlating the signal intensity of AuNP aggregates with the concentration of AFB1. Under the optimal experimental conditions, the lower limit of quantitation for AFB1 was 0.5 fg/mL, the quantitation range was 0.5-1000 fg/mL, and the relative standard deviation was 3.2 % (c = 200 fg/mL, n = 7). The accuracy of the method was verified by the determination of AFB1 in quality control corn meal sample, revealing the method can be used to detect AFB1 in complex food matrix. The method was successfully applied to the detection of AFB1 in rice, wheat and peanut samples. The developed method has the advantages of high sensitivity, good specificity, and ease of operation, providing a new approach for toxin analysis in various food.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aflatoxin B1Metal NanoparticlesMass SpectrometryAptamers, NucleotideGoldLimit of DetectionFood Contamination

Stichwörter der Autor:innen

Aflatoxin B1AuNPs elemental labelingFoodHomogeneous detectionSingle particle (SP)-ICP-MS

Substanzen

Aflatoxin B1Aptamers, NucleotideGold

Autor:innen und Institutionen

  • Department of Chemistry, Wuhan University, Wuhan, 430072, China.
  • Department of Chemistry, Wuhan University, Wuhan, 430072, China. Electronic address: bbchen@whu.edu.cn.

Förderung

  • Ministry of Education of the People's Republic of China
  • National Natural Science Foundation of China

Zitieren

APA

Guo, T., He, M., Chen, B., & Hu, B. (2026). A homogeneous assay for highly sensitive determination of aflatoxin B1 by elemental labeling single-particle inductively coupled plasma mass spectrometry. Talanta. https://doi.org/10.1016/j.talanta.2025.129161

Vancouver

Guo T, He M, Chen B, Hu B. A homogeneous assay for highly sensitive determination of aflatoxin B1 by elemental labeling single-particle inductively coupled plasma mass spectrometry. Talanta. 2026. doi:10.1016/j.talanta.2025.129161

BibTeX
@article{Guo2026,
  author = {Guo, Ting and He, Man and Chen, Beibei and Hu, Bin},
  title = {A homogeneous assay for highly sensitive determination of aflatoxin B1 by elemental labeling single-particle inductively coupled plasma mass spectrometry},
  journal = {Talanta},
  year = {2026},
  doi = {10.1016/j.talanta.2025.129161}
}
Kostenlos starten →