EUVIMEDEUVIMED entdecken
Crossref

Deep eutectic solvents with low viscosity for automation of liquid-phase microextraction based on lab-in-syringe system: Separation of Sudan dyes

Andrey Shishov, Aleksei Pochivalov, Ivan Dubrovsky, Andrey Bulatov

Talanta · 2023-04 · 255 · 124243

DOI: 10.1016/j.talanta.2022.124243 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Talanta, 2023-04. Verfasst von Andrey Shishov und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universi…. Hauptthemen laut MEDLINE: Liquid Phase Microextraction. Die Arbeit wurde bisher 63-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Russian Science Foundation, Saint Petersburg State University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the work limitations of deep eutectic solvents in the flow-based analysis are discussed. Deep eutectic solvents based on terpenes and fatty acids with low viscosity were studied as extraction solvents for liquid-liquid microextraction into a lab-in-syringe system for the first time. As a result an automated deep eutectic solvent-based microextraction approach was proposed. The procedure involved aspiration of deep eutectic solvent (based on terpene and fatty acid) and aqueous sample solution followed by phases mixing by a magnetic stirrer inside a syringe of flow system. After phase separation the extract phase was transferred from the syringe into a vial followed by analysis by a high-performance liquid chromatography with diode-array detection. The determination of Sudan I, Sudan II and Sudan III in chili-based sauces was considered as an analytical task. The mass-transfer intensification performed by the magnetic stirring inside the syringe allowed to perform fast (2 min) and efficient (extraction recoveries 87-95%) extraction. The limits of detection, calculated from a blank test based on 3σ, were from 0.003 to 0.005 mg kg-1, RSD was

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Liquid Phase MicroextractionDeep Eutectic SolventsSyringesColoring AgentsViscositySolventsFatty AcidsAutomationLimit of Detection

Stichwörter der Autor:innen

Chili-based sauceDeep eutectic solventHPLC-DADLab-in-syringeLiquid-phase microextractionSudan dyesViscosity

Substanzen

Deep Eutectic SolventsColoring AgentsSolventsFatty Acids

Autor:innen und Institutionen

  • Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya Nab., St. Petersburg, 199034, Russia. Electronic address: and…
  • Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, Saint Petersburg State University, SPbSU, SPbU, 7/9 Universitetskaya Nab., St. Petersburg, 199034, Russia.

Förderung

  • Russian Science Foundation
  • Saint Petersburg State University

Zitieren

APA

Shishov, A., Pochivalov, A., Dubrovsky, I., & Bulatov, A. (2023). Deep eutectic solvents with low viscosity for automation of liquid-phase microextraction based on lab-in-syringe system: Separation of Sudan dyes. Talanta, 255, 124243. https://doi.org/10.1016/j.talanta.2022.124243

Vancouver

Shishov A, Pochivalov A, Dubrovsky I, Bulatov A. Deep eutectic solvents with low viscosity for automation of liquid-phase microextraction based on lab-in-syringe system: Separation of Sudan dyes. Talanta. 2023;255:124243. doi:10.1016/j.talanta.2022.124243

BibTeX
@article{Shishov2023,
  author = {Shishov, Andrey and Pochivalov, Aleksei and Dubrovsky, Ivan and Bulatov, Andrey},
  title = {Deep eutectic solvents with low viscosity for automation of liquid-phase microextraction based on lab-in-syringe system: Separation of Sudan dyes},
  journal = {Talanta},
  year = {2023},
  volume = {255},
  pages = {124243},
  doi = {10.1016/j.talanta.2022.124243}
}
Kostenlos starten →