The reduction of FIB damage on cryo-lamella by lowering energy of ion beam revealed by a quantitative analysis
Structure · 2023-10 · 31 (10) · 1275-1281.e4
DOI: 10.1016/j.str.2023.07.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Structure, 2023-10. Verfasst von Qi Yang und 5 weiteren Autor:innen. Beteiligte Einrichtung: National Laboratory of Biomacromolecules, CAS Center for Excellence in Biomacromolecules, Institute of Biophysics, Chinese Academy of Sciences (CAS),…. Hauptthemen laut MEDLINE: Cryoelectron Microscopy. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
Focused ion beam (FIB) is widely used for thinning frozen cells to produce lamellae for cryo-electron microscopy imaging and for protein structures study in vivo. However, FIB damages the lamellae and a quantitative experimental analysis of the damage is lacking. We used a 30-keV gallium FIB to prepare lamellae of a highly concentrated icosahedral virus sample. The viruses were grouped according to their distance from the surface of lamellae and reconstructed. Damage to the approximately 20-nm-thick outermost lamella surface was similar to that from exposure to 16 e-/Å2 in a 300-kV cryo-electron microscope at high-resolution range. The damage was negligible at a depth beyond 50 nm, which was reduced to 30 nm if 8-keV Ga+ was used during polishing. We designed extra steps in the reconstruction refinement to maximize undamaged signals and increase the resolution. The results demonstrated that low-energy beam polishing was essential for high-quality thinner lamellae.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- National Laboratory of Biomacromolecules, CAS Center for Excellence in Biomacromolecules, Institute of Biophysics, Chinese Academy of Sciences (CAS), Beijing 100101, P.R. China; University of Chinese Academy of Sciences…
- National Laboratory of Biomacromolecules, CAS Center for Excellence in Biomacromolecules, Institute of Biophysics, Chinese Academy of Sciences (CAS), Beijing 100101, P.R. China.
- National Laboratory of Biomacromolecules, CAS Center for Excellence in Biomacromolecules, Institute of Biophysics, Chinese Academy of Sciences (CAS), Beijing 100101, P.R. China. Electronic address: xzzhang@ibp.ac.cn.
Zitieren
APA
Yang, Q., Wu, C., Zhu, D., Li, J., Cheng, J., & Zhang, X. (2023). The reduction of FIB damage on cryo-lamella by lowering energy of ion beam revealed by a quantitative analysis. Structure, 31(10), 1275-1281.e4. https://doi.org/10.1016/j.str.2023.07.002
Vancouver
Yang Q, Wu C, Zhu D, Li J, Cheng J, Zhang X. The reduction of FIB damage on cryo-lamella by lowering energy of ion beam revealed by a quantitative analysis. Structure. 2023;31(10):1275-1281.e4. doi:10.1016/j.str.2023.07.002
BibTeX
@article{Yang2023,
author = {Yang, Qi and Wu, Chunling and Zhu, Dongjie and Li, Junxi and Cheng, Jing and Zhang, Xinzheng},
title = {The reduction of FIB damage on cryo-lamella by lowering energy of ion beam revealed by a quantitative analysis},
journal = {Structure},
year = {2023},
volume = {31},
number = {10},
pages = {1275--1281.e4},
doi = {10.1016/j.str.2023.07.002}
}
EUVIMED