EUVIMEDEUVIMED entdecken
ValidierungsstudieBeobachtungsstudieOpen Access · CC BY 4.0

Validity, reliability, and responsiveness of a low-cost activity monitor for assessing walking in patients with lumbar spinal stenosis

Paraskevi Drakoulidou, Michael Knox, Biara M Webster, James Meares, Christella Mylordi, Raoul Pope, Omprakash Damodaran, James M van Gelder, David B Anderson

The Spine Journal · 2026-01 · 26 (1) · 94-105

DOI: 10.1016/j.spinee.2025.07.017 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift The Spine Journal, 2026-01. Verfasst von Paraskevi Drakoulidou und 8 weiteren Autor:innen. Beteiligte Einrichtung: Sydney Spine Institute, 107/3 Railway Parade, Burwood, NSW, 2173, Australia. Hauptthemen laut MEDLINE: Spinal Stenosis, Walking, Lumbar Vertebrae. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Sydney.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND CONTEXT: Reduced walking capacity is the hallmark of lumbar spinal stenosis (LSS). Currently, walking capacity in LSS is assessed with self-reported questionnaires. The Self-Paced Walking Test (SPWT) has been recommended as an objective capture of walking capacity, but takes up to 30 minutes to complete, preventing its widespread use by clinicians. Consumer-based activity monitors and smartphones have been suggested as an alternative but have not been validated in the LSS population. PURPOSE: To determine the measurement properties of criterion validity, reliability and responsiveness of a low-cost consumer-based wrist activity monitor, smartphone walking app, SPWT and 2 patient-reported outcomes, the Oswestry Disability Index (ODI) walk item and the Physical Function Scale of the Swiss Spinal Stenosis Questionnaire (PFS) within an LSS population. STUDY DESIGN/SETTING: Measurement properties study utilizing observational cohort design. PATIENT SAMPLE: A total of 124 subjects with LSS (confirmed by a spinal surgeon from a combination of imaging and clinical symptoms) were recruited prospectively from the private consulting rooms of 3 spinal surgeons between May 2019 and August 2023. OUTCOME MEASURES: Wrist activity monitor distance, smartphone walking app distance, SPWT, ODI walk item, and PFS from the Swiss Spinal Stenosis Questionnaire. METHODS: Walking capacity was assessed on 3 occasions, with the first/baseline assessment before surgery. The first assessment was conducted to determine the criterion validity of the wrist activity monitor, phone app, ODI walk item and PFS by comparison against the SPWT. The reliability of all 5 walking capacity measures was assessed 1-3 weeks following initial assessment. Responsiveness was assessed in a subset of participants following their spinal procedure. Responsiveness was calculated using both the SPWT and a self-perceived recovery scale as the external anchor. COSMIN criteria was used to determine adequate and inadequate results for each measurement property. RESULTS: Criterion validity of the activity monitor (n=123) and smartphone app (n=89) was strong with r=0.96 and r=0.93, respectively. There was only a moderate correlation between the SPWT and subjective walking measures ODI (n=121) and PFS (n=123) with r=-0.33 and r=-0.39 respectively. Objective measures of walking capacity demonstrated excellent reliability based on the intraclass correlation coefficient (ICC) results. The activity monitor, smartphone application and SPWT showed an ICC of 0.96, 0.97, and 0.96, respectively. The PFS showed good reliability (ICC=0.76) while the reliability of the ODI walk item was poor (ICC=0.45). When responsiveness was assessed based on self-perceived recovery, only the PFS demonstrated acceptable responsiveness with an Area Under the Curve (AUC) value of 0.73. Responsiveness anchored on SPWT distance was excellent for the activity monitor (AUC=1.00) and the smartphone application (AUC=1.00), but neither the ODI walking (AUC=0.69) nor PFS (AUC=0.50) demonstrated acceptable responsiveness. CONCLUSIONS: A low-cost wrist activity monitor and phone walking app are valid, reliable, and responsive measures of walking capacity in LSS and can be recommended in clinical and research assessment. These measures can overcome the existing barriers in the use of objective measures. These measures may also support a move away from single time-point measures of LSS, that could allow clinicians and researchers to capture the fluctuation in walking capacity evident in people with LSS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spinal StenosisWalkingLumbar VertebraeHumansFemaleMaleReproducibility of ResultsAgedMiddle AgedDisability EvaluationPatient Reported Outcome MeasuresMobile ApplicationsSmartphoneWalk Test

Stichwörter der Autor:innen

Back painMeasurement propertiesMusculoskeletal painNeuromuscular diseaseNeurosurgeryOutcome measureSpinal canalSpinal stenosisSpine

Autor:innen und Institutionen

  • Sydney Spine Institute, 107/3 Railway Parade, Burwood, NSW, 2173, Australia.
  • Sydney Spine Institute, 107/3 Railway Parade, Burwood, NSW, 2173, Australia; Graduate School of Health, University of Technology Sydney, 100 Broadway, UTS Building 20, Ultimo, NSW, 2007, Australia.
  • Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, City Road, NSW, 2006, Australia.
  • Neurosurgical Department, Concord Repatriation General Hospital, Building 44, Hospital Road, Concord, Sydney, NSW, 2139, Australia.
  • Sydney Spine Institute, 107/3 Railway Parade, Burwood, NSW, 2173, Australia; Neurosurgical Department, Concord Repatriation General Hospital, Building 44, Hospital Road, Concord, Sydney, NSW, 2139, Australia; School of…
  • Sydney Spine Institute, 107/3 Railway Parade, Burwood, NSW, 2173, Australia; Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, City Road, NSW, 2006, Australia. Electronic addres…

Förderung

  • University of Sydney

Zitieren

APA

Drakoulidou, P., Knox, M., Webster, B. M., Meares, J., Mylordi, C., Pope, R., Damodaran, O., van Gelder, J. M., & Anderson, D. B. (2026). Validity, reliability, and responsiveness of a low-cost activity monitor for assessing walking in patients with lumbar spinal stenosis. The Spine Journal, 26(1), 94-105. https://doi.org/10.1016/j.spinee.2025.07.017

Vancouver

Drakoulidou P, Knox M, Webster BM, Meares J, Mylordi C, Pope R, et al. Validity, reliability, and responsiveness of a low-cost activity monitor for assessing walking in patients with lumbar spinal stenosis. The Spine Journal. 2026;26(1):94-105. doi:10.1016/j.spinee.2025.07.017

BibTeX
@article{Drakoulidou2026,
  author = {Drakoulidou, Paraskevi and Knox, Michael and Webster, Biara M and Meares, James and Mylordi, Christella and Pope, Raoul and Damodaran, Omprakash and van Gelder, James M and Anderson, David B},
  title = {Validity, reliability, and responsiveness of a low-cost activity monitor for assessing walking in patients with lumbar spinal stenosis},
  journal = {The Spine Journal},
  year = {2026},
  volume = {26},
  number = {1},
  pages = {94--105},
  doi = {10.1016/j.spinee.2025.07.017}
}