EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY 4.0

Accurate placement of thoracolumbar pedicle screws using a handheld iOS-based navigation device: a prospective intra-patient agreement study

Mark P Arts, Geert Lycklama À Nijeholt, Eddie Van Eeckhoven, Jasper F C Wolfs

The Spine Journal · 2024-09 · 24 (9) · 1671-1677

DOI: 10.1016/j.spinee.2024.04.033 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift The Spine Journal, 2024-09. Verfasst von Mark P Arts und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Haaglanden Medical Center, PO Box 432, 2501 CK, The Hague, The Netherlands. Electronic address: m.arts@haaglandenmc.nl. Hauptthemen laut MEDLINE: Lumbar Vertebrae, Pedicle Screws, Thoracic Vertebrae. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Accurate pedicle screw placement is a challenge with reported misplacement rates of 10% and higher. A handheld navigation device (HND) may provide accuracy equal to CT-based navigation (CT-Nav) but without the cost and complexity. OBJECTIVE: To study the accuracy of a handheld navigation device for pedicle screw placement. STUDY DESIGN: This prospective cross-sectional study with consistently applied reference standard enrolled 20 patients undergoing 92 pedicle screw placements. PATIENTS: Patients who underwent pedicle screw placement between May 2022 and September 2022. OUTCOME MEASURES: Pedicle screw placement accuracy per Gertzbein-Robbins. METHODS: Once the screw pilot hole was established, the proposed trajectory of the HND was compared with that proposed by CT-Nav. Postoperatively, screw accuracy was graded according to Gertzbein-Robbins by a blinded radiologist based on CT scans. Accuracy was compared between the two systems and published control for fluoroscopy assisted and CT-Nav placement using Bayesian posterior distribution. RESULTS: The trajectory proposed by the HND and CT-Nav were in agreement in 98.9% (95% Exact CI; 94.09%-99.97%). The HND accuracy was 98.9% with 91 screws rated "A" and 1 rated "C". Noninferiority to fluoroscopic placement was achieved because the one-sided normal-approximation 95% CI Lower Bound (LB) of 95.3% is greater than the Performance Goal (PG) of 83.4%. Posthoc analysis demonstrated that the probability of superiority of the HND relative to the historical accuracy rate of 91.5% for fluoroscopy assisted procedures is >0.999 and that the HND's accuracy rate is within 4.5% of CT-Nav of 95.5% is >0.999. No adverse events or intra-operative complications associated with HND were observed. There was 1 (1.1%) intra-operative repositioning and no reoperations for any reason. CONCLUSIONS: The accuracy rate of the HND was 98.9%, and the proposed trajectory matched with CT-Nav in 98.9% of the time. This is superior to the historical published accuracy rate for fluoroscopy-assisted procedures and equivalent to the historical published accuracy rate for CT-Nav. CLINICAL TRIAL REGISTRATION NUMBER: Dutch trial register NL74268.058.20.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lumbar VertebraePedicle ScrewsThoracic VertebraeAdultAgedFemaleHumansMaleMiddle AgedCross-Sectional StudiesFluoroscopyProspective StudiesSpinal FusionSurgery, Computer-AssistedSurgical Navigation SystemsTomography, X-Ray Computed

Stichwörter der Autor:innen

AccuracyAgreement studyComplicationsFully pairedGertzbein–Robbins scaleGuidanceHandheld navigation deviceNavigationPedicle screw

Autor:innen und Institutionen

  • Department of Neurosurgery, Haaglanden Medical Center, PO Box 432, 2501 CK, The Hague, The Netherlands. Electronic address: m.arts@haaglandenmc.nl.
  • Department of Radiology, Haaglanden Medical Center, PO Box 432, 2501 CK, The Hague, The Netherlands.
  • Eeckhoven BV, Kon. Astridlaan 51, 2550, Kontich, Belgium.
  • Department of Neurosurgery, Haaglanden Medical Center, PO Box 432, 2501 CK, The Hague, The Netherlands.

Zitieren

APA

Arts, M. P., Lycklama À Nijeholt, G., Van Eeckhoven, E., & Wolfs, J. F. C. (2024). Accurate placement of thoracolumbar pedicle screws using a handheld iOS-based navigation device: a prospective intra-patient agreement study. The Spine Journal, 24(9), 1671-1677. https://doi.org/10.1016/j.spinee.2024.04.033

Vancouver

Arts MP, Lycklama À Nijeholt G, Van Eeckhoven E, Wolfs JFC. Accurate placement of thoracolumbar pedicle screws using a handheld iOS-based navigation device: a prospective intra-patient agreement study. The Spine Journal. 2024;24(9):1671-1677. doi:10.1016/j.spinee.2024.04.033

BibTeX
@article{Arts2024,
  author = {Arts, Mark P and Lycklama À Nijeholt, Geert and Van Eeckhoven, Eddie and Wolfs, Jasper F C},
  title = {Accurate placement of thoracolumbar pedicle screws using a handheld iOS-based navigation device: a prospective intra-patient agreement study},
  journal = {The Spine Journal},
  year = {2024},
  volume = {24},
  number = {9},
  pages = {1671--1677},
  doi = {10.1016/j.spinee.2024.04.033}
}
Kostenlos starten →