EUVIMEDEUVIMED entdecken
Crossref

Posterior atlantoaxial fixation of osteoporotic odontoid fracture: biomechanical analysis of the Magerl versus harms techniques in a cadaver model

Austin Mike-Mayer, Kendrick Lam, Randal P Morris, Abeer Al Barghouthi, Francesco Travascio, Loren L Latta, Ronald W Lindsey

The Spine Journal · 2024

DOI: 10.1016/j.spinee.2024.04.017 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Spine Journal, 2024. Verfasst von Austin Mike-Mayer und 6 weiteren Autor:innen. Beteiligte Einrichtung: The Department of Orthopedic Surgery and Rehabilitation, The University of Texas Medical Branch, 301 University Blvd., Galveston, TX, USA. Hauptthemen laut MEDLINE: Odontoid Process, Spinal Fractures, Atlanto-Axial Joint, Cadaver. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND CONTEXT: Odontoid fractures are among the most common cervical spine fractures in the elderly and are associated with increased morbidity and mortality. Clinical evidence suggests improved survival and quality of life after operative intervention compared to nonoperative treatment. PURPOSE: This study seeks to examine the stability of an osteoporotic Type II odontoid fracture following posterior atlantoaxial fixation with either the Magerl transarticular fixation technique or the Harms C1 lateral mass screws C2 pedicle screw rod fixation. STUDY DESIGN: Biomechanical cadaveric study. METHODS: Eighteen cadaveric specimens extending from the cephalus to C7 were used in this study. Reflective marker arrays were attached to C1 and C2 and a single marker on the dens to measure movement of each during loading with C2-C3 and occiput-C1 being allowed to move freely. A biomechanical testing protocol imparted moments in flexion-extension, axial rotation, and lateral bending while a motion capture system recorded the motions of C1, C2, and the dens. The spines were instrumented with either the Harms fixation (n=9) or Magerl fixation (n=9) techniques, and a simulated Type II odontoid fracture was created. Motions of each instrumented spine were recorded for all moments, and then again after the instrumentation was removed to model the injured, noninstrumented state. RESULTS: Both Harms and Magerl posterior C1-C2 fixation allowed for C1, C2, and the dens to move as a relative unit. Without fixation the dens motion was coupled with C1. No significant differences were found in X, Y, Z translation motion of the dens, C1 or C2 during neutral zone motions between the Magerl and Harms fixation techniques. There were no significant differences found in Euler angle motion between the two techniques in either flexion-extension, axial rotation, or lateral bending motion. CONCLUSIONS: Our findings suggest that both Harms and Magerl fixation can significantly reduce dens motion in Type II odontoid fractures in an osteoporotic cadaveric bone model. CLINICAL SIGNIFICANCE: Both Harms and Magerl posterior atlantoaxial fixation techniques allowed for C1, C2, and the dens to move as a relative unit following odontoid fracture, establishing more anatomic stability to the upper cervical spine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Odontoid ProcessSpinal FracturesAtlanto-Axial JointCadaverHumansBiomechanical PhenomenaAgedFracture Fixation, InternalOsteoporotic FracturesMaleSpinal FusionFemaleCervical VertebraeAged, 80 and overPedicle Screws

Stichwörter der Autor:innen

BiomechanicsCervical spineCervical vertebraeFracture fixationMagerl techniqueOdontoid processOsteoporosis of the spineSpinal fractures

Autor:innen und Institutionen

  • The Department of Orthopedic Surgery and Rehabilitation, The University of Texas Medical Branch, 301 University Blvd., Galveston, TX, USA.
  • Mount Sinai Medical Center, Max Biedermann Institute for Biomechanics, 4300 Alton Rd., Miami Beach, FL, USA.
  • The Department of Orthopedic Surgery and Rehabilitation, The University of Texas Medical Branch, 301 University Blvd., Galveston, TX, USA. Electronic address: rmorris@utmb.edu.
  • Mount Sinai Medical Center, Max Biedermann Institute for Biomechanics, 4300 Alton Rd., Miami Beach, FL, USA; Department of Mechanical and Aerospace Engineering, University of Miami, 1251 Memorial Dr., Coral Gables, FL,…
  • Mount Sinai Medical Center, Max Biedermann Institute for Biomechanics, 4300 Alton Rd., Miami Beach, FL, USA; Department of Orthopaedics, University of Miami, 1611 NW 12th Ave #303, Miami, FL, USA.

Zitieren

APA

Mike-Mayer, A., Lam, K., Morris, R. P., Barghouthi, A. A., Travascio, F., Latta, L. L., & Lindsey, R. W. (2024). Posterior atlantoaxial fixation of osteoporotic odontoid fracture: biomechanical analysis of the Magerl versus harms techniques in a cadaver model. The Spine Journal. https://doi.org/10.1016/j.spinee.2024.04.017

Vancouver

Mike-Mayer A, Lam K, Morris RP, Barghouthi AA, Travascio F, Latta LL, et al. Posterior atlantoaxial fixation of osteoporotic odontoid fracture: biomechanical analysis of the Magerl versus harms techniques in a cadaver model. The Spine Journal. 2024. doi:10.1016/j.spinee.2024.04.017

BibTeX
@article{MikeMayer2024,
  author = {Mike-Mayer, Austin and Lam, Kendrick and Morris, Randal P and Barghouthi, Abeer Al and Travascio, Francesco and Latta, Loren L and Lindsey, Ronald W},
  title = {Posterior atlantoaxial fixation of osteoporotic odontoid fracture: biomechanical analysis of the Magerl versus harms techniques in a cadaver model},
  journal = {The Spine Journal},
  year = {2024},
  doi = {10.1016/j.spinee.2024.04.017}
}
Kostenlos starten →