Development of reusable screen-printed ion-selective electrodes with calibration-free operation
Sensors and Actuators Reports · 2025-12 · 10 · 100367
DOI: 10.1016/j.snr.2025.100367 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors and Actuators Reports, 2025-12. Verfasst von Pavel Sengupta und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Oregon State University, Corvallis, OR 97331, USA. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIDCR NIH HHS, National Institute of Dental and Craniofacial Research.
Abstract (Originalsprache)
The reusable solid-state calibration-free screen-printed ion-selective electrodes (SP-ISEs) have been developed with a carbon paste and PEDOT: PEDOT-S (S=sulfonated) back contact. The calibration-free Na+ and Ca2+ SP-ISEs showed a near Nernstian response of 52.1 ± 2.0 mV/log [aNa+] and 27.3 ± 0.8 mV/log [aCa2+] respectively while holding a stable intercept for multiple calibrations across batches for 12 h and over 7 days. The unique carbon paste and PEDOT: PEDOT-S copolymer combined back contact on carbon substrate allowed us to fix the intercept with a constant low current treatment across different ionophores for both monovalent Na+ and divalent Ca2+ cations. This treatment imparts exceptional potential stability, leading to highly overlapping calibration curves for individual ISEs across multiple measurement cycles, demonstrating their reusability in a calibration-free mode. These SP-ISEs maintained their respective selectivity against major interfering ions and were able to operate reproducibly despite prolonged dry storage without any curing solution, as tested for a total of 28 days. The practical utility of these sensors was validated by analyzing environmental samples, determining Na+ and Ca2+ concentrations in tap water (934 ± 37 μM and 194 ± 11 μM respectively) and hydroponics solutions (757 ± 43 μM and 7047 ± 565 μM respectively). This integration of high-performance characteristics on an economical carbon-based substrate creates sensors that are simultaneously affordable enough to be disposable yet stable enough to be reusable, effectively bridging the critical gap between sophisticated laboratory systems and scalable, field-deployable solid ISEs for environmental monitoring applications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemistry, Oregon State University, Corvallis, OR 97331, USA.
ORCID-Profile: Dipankar Koley
Förderung
- NIDCR NIH HHS
- National Institute of Dental and Craniofacial Research
Zitieren
APA
Sengupta, P., Ramsperger, C., & Koley, D. (2025). Development of reusable screen-printed ion-selective electrodes with calibration-free operation. Sensors and Actuators Reports, 10, 100367. https://doi.org/10.1016/j.snr.2025.100367
Vancouver
Sengupta P, Ramsperger C, Koley D. Development of reusable screen-printed ion-selective electrodes with calibration-free operation. Sensors and Actuators Reports. 2025;10:100367. doi:10.1016/j.snr.2025.100367
BibTeX
@article{Sengupta2025,
author = {Sengupta, Pavel and Ramsperger, Chloe and Koley, Dipankar},
title = {Development of reusable screen-printed ion-selective electrodes with calibration-free operation},
journal = {Sensors and Actuators Reports},
year = {2025},
volume = {10},
pages = {100367},
doi = {10.1016/j.snr.2025.100367}
}
EUVIMED