EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Hydrogen peroxide sensing with cochlear implants in vivo: Towards intra-operative trauma detection

Jolan Wellens, Lore Kerkhofs, Olivier Deschaume, Tristan Putzeys, Filippo Franceschini, Irene Taurino, Patrick Wagner, Myles Mc Laughlin, Nicolas Verhaert, Carmen Bartic

Sensors and Actuators B: Chemical · 2025-09 · 438 · 137789

DOI: 10.1016/j.snb.2025.137789 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors and Actuators B: Chemical, 2025-09. Verfasst von Jolan Wellens und 9 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: KU Leuven, Research Foundation Flanders, KU Leuven Research Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Despite advancements in soft surgical techniques and electrodes, intra-cochlear trauma during cochlear implant (CI) insertion still occurs and can harm microstructures through inflammation and formation of fibrosis, affecting residual hearing. Yet detection and imaging techniques to study the cochlear microenvironment during insertion in vivo are currently lacking. Implantable hydrogen peroxide sensors could address this issue since hydrogen peroxide is linked to acute and chronic inflammation. Here, we modified CI electrode arrays to function as electrochemical hydrogen peroxide sensors. Modifications included electrodeposition of iridium oxide (IrOx) as a quasi-reference electrode, a poly(o-phenylenediamine) permselective membrane, and a sulfobetaine antifouling layer to improve selectivity and prevent biofouling. These modifications were first characterized on microfabricated platinum test electrodes, showing stable IrOx potentials for 28 days in artificial perilymph and resistance to macrophage and fibroblast adhesion. The CI sensors demonstrated a peroxide detection limit of 2.5 μM in vitro . In vivo testing in a gerbil model showed elevated hydrogen peroxide levels (from 61 ± 4 μM to 114 ± 8 μM) following insertion trauma confirmed by contrast-enhanced micro-CT. However, while IrOx was stable in vitro , it showed a 40 mV drift over 6 hours in vivo . These findings highlight the potential of using CI electrode arrays to monitor implantation-induced trauma and inflammation, by correlating between measured hydrogen peroxide levels and trauma severity while highlighting the need for improving in vivo stability. Further research is needed to improve the stability of IrOx reference electrodes and understand the correlation between hydrogen peroxide and trauma severity. • A simple modification of cochlear implants (CI) for intracochlear H 2 O 2 detection. • Electrodeposited iridium oxide on CI as a reference electrode in artificial perilymph. • CI peroxide sensor limit of detection as low as 2.5 μM with limited interference. • In vivo intra-operative H 2 O 2 concentration measured in the cochlea of a gerbil. • H 2 O 2 concentration increase in the cochlea is correlated with trauma.

Förderung

  • KU Leuven
  • Research Foundation Flanders
  • KU Leuven Research Council

Zitieren

APA

Wellens, J., Kerkhofs, L., Deschaume, O., Putzeys, T., Franceschini, F., Taurino, I., Wagner, P., Laughlin, M. M., Verhaert, N., & Bartic, C. (2025). Hydrogen peroxide sensing with cochlear implants in vivo: Towards intra-operative trauma detection. Sensors and Actuators B: Chemical, 438, 137789. https://doi.org/10.1016/j.snb.2025.137789

Vancouver

Wellens J, Kerkhofs L, Deschaume O, Putzeys T, Franceschini F, Taurino I, et al. Hydrogen peroxide sensing with cochlear implants in vivo: Towards intra-operative trauma detection. Sensors and Actuators B: Chemical. 2025;438:137789. doi:10.1016/j.snb.2025.137789

BibTeX
@article{Wellens2025,
  author = {Wellens, Jolan and Kerkhofs, Lore and Deschaume, Olivier and Putzeys, Tristan and Franceschini, Filippo and Taurino, Irene and Wagner, Patrick and Laughlin, Myles Mc and Verhaert, Nicolas and Bartic, Carmen},
  title = {Hydrogen peroxide sensing with cochlear implants in vivo: Towards intra-operative trauma detection},
  journal = {Sensors and Actuators B: Chemical},
  year = {2025},
  volume = {438},
  pages = {137789},
  doi = {10.1016/j.snb.2025.137789}
}
Kostenlos starten →