EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Droplet microfluidic platform for extracellular vesicle isolation based on magnetic bead handling

Alessio Meggiolaro, Valentina Moccia, Alessandro Sammarco, Paola Brun, Carlotta Caterina Damanti, Beatrice Crestani, Lara Mussolin, Matteo Pierno, Giampaolo Mistura, Valentina Zappulli, Davide Ferraro

Sensors and Actuators B: Chemical · 2024-06 · 409 · 135583

DOI: 10.1016/j.snb.2024.135583 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors and Actuators B: Chemical, 2024-06. Verfasst von Alessio Meggiolaro und 10 weiteren Autor:innen. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Associazione Italiana per la Ricerca sul Cancro, Ministero dell'Istruzione dell'Universita e della Ricerca, European Commission.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Extracellular vesicles (EVs) are rapidly gaining in popularity as biomarkers of various diseases, acting as cargoes of valuable information from the cell of origin. Despite their important value, their current use in clinical practice is still limited. Among the limiting factors, one of the most critical are the challenges regarding their isolation. In fact, conventional approaches are characterized by low purity and throughput, or poor reproducibility. Here, we present a droplet microfluidic platform specifically developed for EV isolation by affinity capture with magnetic beads. This platform is capable of processing large sample volumes (2 mL) in a relatively short time (4.5 hours), with considerable automation. In detail, EVs and magnetic beads are co-encapsulated within the same droplet, which acts promoting their mixing due to the spontaneous recirculation; this continuous agitation prevents any loss usually caused by bead sedimentation and promotes the EV capturing. Our droplet microfluidic protocol is compared to a commercially available method, showing a shorter required incubation time (about 2.5 times) and a higher capture efficiency (2.5-folds). The microfluidic approach is therefore positively evaluated in terms of protein content, EV quantification and microRNA cargo analysis.

Förderung

  • Associazione Italiana per la Ricerca sul Cancro
  • Ministero dell'Istruzione dell'Universita e della Ricerca
  • European Commission
  • Universita degli Studi di Padova
  • BIRD Foundation
  • Ministero dell’Istruzione, dell’Università e della Ricerca

Zitieren

APA

Meggiolaro, A., Moccia, V., Sammarco, A., Brun, P., Damanti, C. C., Crestani, B., Mussolin, L., Pierno, M., Mistura, G., Zappulli, V., & Ferraro, D. (2024). Droplet microfluidic platform for extracellular vesicle isolation based on magnetic bead handling. Sensors and Actuators B: Chemical, 409, 135583. https://doi.org/10.1016/j.snb.2024.135583

Vancouver

Meggiolaro A, Moccia V, Sammarco A, Brun P, Damanti CC, Crestani B, et al. Droplet microfluidic platform for extracellular vesicle isolation based on magnetic bead handling. Sensors and Actuators B: Chemical. 2024;409:135583. doi:10.1016/j.snb.2024.135583

BibTeX
@article{Meggiolaro2024,
  author = {Meggiolaro, Alessio and Moccia, Valentina and Sammarco, Alessandro and Brun, Paola and Damanti, Carlotta Caterina and Crestani, Beatrice and Mussolin, Lara and Pierno, Matteo and Mistura, Giampaolo and Zappulli, Valentina and Ferraro, Davide},
  title = {Droplet microfluidic platform for extracellular vesicle isolation based on magnetic bead handling},
  journal = {Sensors and Actuators B: Chemical},
  year = {2024},
  volume = {409},
  pages = {135583},
  doi = {10.1016/j.snb.2024.135583}
}
Kostenlos starten →