Dynamic Evaluation of Peripheral Hypoxia (DEPH): a method for the assessment of nocturnal hypoxic burden in respiratory diseases using pulse-oximetry
Sleep Medicine · 2026-10 · 146 · 109103
DOI: 10.1016/j.sleep.2026.109103 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sleep Medicine, 2026-10. Verfasst von Pasquale Tondo und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical and Surgical Sciences, University of Foggia, Foggia, Italy; Respiratory and Intensive Care Unit (RICU), Department of Specialis…. Hauptthemen laut MEDLINE: Hypoxia, Oximetry, Sleep Apnea, Obstructive. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Nocturnal hypoxic burden (HB) has been described using multiple algorithmic definitions, each based on different assumptions regarding signal segmentation and baseline reference, in obstructive sleep apnea (OSA). However, existing approaches share several methodological limitations and lack a standardized unit of measurement. These metrics have been applied almost exclusively in OSA and only on polysomnographic recordings, rendering the resulting indices non-comparable across methods. To address these gaps, we introduce the Dynamic Evaluation of Peripheral Hypoxia (DEPH), a method applicable to nocturnal pulse-oximetry and across heterogeneous respiratory diseases.
Methods
A retrospective analysis was conducted on 1,000 consecutive nocturnal pulse-oximetry recordings from patients with heterogeneous chronic respiratory disorders referred for suspected nocturnal hypoxemia. DEPH was designed to express HB as a dimensionless measure through the ratio of two areas (desaturation area/global area). The performance of DEPH was compared with that of three other methods (HB 100 , fixed 100% SpO 2 baseline; HB 90 , fixed 90% baseline; HB FA , fully automated) already used for HB determination, after standardizing the HB (sHB), so that the resulting indices were directly comparable.
Results
The cohort had a mean age of 65.9±13.1 years (60% male) and a mean BMI of 34.6±9.0 kg·m -2 . Mean SpO 2 was 90.0±4.7%, nadir 75.3±10.6%, SpO 2 stDev 2.8±1.8% and T90 34.4±33.9%, reflecting marked variability in oximetric patterns across individuals. The estimation of sHB was statistically different between the four methods used (sHB DEPH 4.1±2.8%, sHB FA 2.4±1.6%, sHB 100 9.8±3.9%, sHB 90 1.9±3.0%, p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical and Surgical Sciences, University of Foggia, Foggia, Italy; Respiratory and Intensive Care Unit (RICU), Department of Specialistic Medicine, Foggia Polyclinic University Hospital, Foggia, Italy. El…
- Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy.
- Department of Medical and Surgical Sciences, University of Foggia, Foggia, Italy; Respiratory and Intensive Care Unit (RICU), Department of Specialistic Medicine, Foggia Polyclinic University Hospital, Foggia, Italy.
Zitieren
APA
Tondo, P., Gallo, C., & Lacedonia, D. (2026). Dynamic Evaluation of Peripheral Hypoxia (DEPH): a method for the assessment of nocturnal hypoxic burden in respiratory diseases using pulse-oximetry. Sleep Medicine, 146, 109103. https://doi.org/10.1016/j.sleep.2026.109103
Vancouver
Tondo P, Gallo C, Lacedonia D. Dynamic Evaluation of Peripheral Hypoxia (DEPH): a method for the assessment of nocturnal hypoxic burden in respiratory diseases using pulse-oximetry. Sleep Medicine. 2026;146:109103. doi:10.1016/j.sleep.2026.109103
BibTeX
@article{Tondo2026,
author = {Tondo, Pasquale and Gallo, Crescenzio and Lacedonia, Donato},
title = {Dynamic Evaluation of Peripheral Hypoxia (DEPH): a method for the assessment of nocturnal hypoxic burden in respiratory diseases using pulse-oximetry},
journal = {Sleep Medicine},
year = {2026},
volume = {146},
pages = {109103},
doi = {10.1016/j.sleep.2026.109103}
}
EUVIMED