EUVIMEDEUVIMED entdecken
Vergleichsstudie

Identification and quantification of Hypocretin-1/Orexin-A 1-14 and 1-16 fragments in immunopurified cerebrospinal fluid using LC-MS: Comparison with radioimmunoassay (RIA) determinations

Anthony Maus, Daniel Figdore, Sandip Chavan, Chad Ruoff, Lois Krahn, Akhilesh Pandey, Joshua Bornhorst

Sleep Medicine · 2026-09 · 145 · 109006

DOI: 10.1016/j.sleep.2026.109006 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Sleep Medicine, 2026-09. Verfasst von Anthony Maus und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, 55905, USA. Hauptthemen laut MEDLINE: Neuropeptides, Narcolepsy, Tandem Mass Spectrometry, Intracellular Signaling Peptides and Proteins. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: Hypocretin-1/Orexin-A is associated with stabilization of the sleep/wake cycle. Reductions of cerebrospinal fluid (CSF) concentrations of orexin-A, as determined by radioimmunoassay (RIA), are considered consistent with the diagnosis of narcolepsy type 1 (NT1). However, measuring full-length orexin-A by other methods such as liquid chromatography-tandem mass spectrometry (LC-MS/MS) has proven technically challenging. In this investigation, abundant fragments of orexin-A in CSF were identified and quantified using LC-MS, which allowed assessment of the concordance with clinical RIA measurements. METHODS: Orexin-A-related peptides were immunopurified using the antibody employed in the RIA from 80 residual CSF samples submitted to our reference laboratory for RIA testing (n = 31, ≤110 pg/mL (low); n = 15, 111-200 pg/mL (intermediate); n = 34, >200 pg/mL (normal)). Enriched peptides then underwent LC-MS/MS analysis, resulting in identification of abundant orexin-A fragments. Following the identification of fragments, quantitative targeted LC-MS measurements were compared to a clinically relevant RIA assay. RESULTS: Full-length orexin-A was not detected in CSF, but two relatively abundant N-terminal orexin-A fragments, comprising amino acids 1-14 and 1-16, were identified by LC-MS/MS. Comparison with RIA yielded Spearman's correlation coefficients (ρ) of 0.91 and 0.94 for the 1-14 and 1-16 fragments, respectively. Additionally, the LC-MS and RIA method were 88% concordant for orexin-A deficient categorizations characteristic of NT1. CONCLUSIONS: Quantitative measurement of the identified orexin-A peptide fragments via LC-MS may represent a significant advance in diagnostic capabilities for evaluating central hypersomnolence disorders. These findings also lay the foundation for future studies on the diagnostic utility and clinical relevance of these orexin-A fragments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NeuropeptidesNarcolepsyTandem Mass SpectrometryIntracellular Signaling Peptides and ProteinsLiquid Chromatography-Mass SpectrometryPeptide FragmentsHumansOrexinsRadioimmunoassayChromatography, LiquidFemale

Stichwörter der Autor:innen

Hypocretin-1Liquid chromatography-mass spectrometryNarcolepsyOrexin-A

Substanzen

OrexinsNeuropeptidesIntracellular Signaling Peptides and ProteinsHCRT protein, humanPeptide Fragments

Autor:innen und Institutionen

  • Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, 55905, USA.
  • Center for Sleep Medicine, Division of Pulmonary and Sleep Medicine, Mayo Clinic, Scottsdale, AZ, 85054, USA.
  • Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, 55905, USA; Center for Individualized Medicine, Mayo Clinic, Rochester, MN, 55905, USA.
  • Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, 55905, USA. Electronic address: Bornhorst.Joshua@mayo.edu.

Zitieren

APA

Maus, A., Figdore, D., Chavan, S., Ruoff, C., Krahn, L., Pandey, A., & Bornhorst, J. (2026). Identification and quantification of Hypocretin-1/Orexin-A 1-14 and 1-16 fragments in immunopurified cerebrospinal fluid using LC-MS: Comparison with radioimmunoassay (RIA) determinations. Sleep Medicine, 145, 109006. https://doi.org/10.1016/j.sleep.2026.109006

Vancouver

Maus A, Figdore D, Chavan S, Ruoff C, Krahn L, Pandey A, et al. Identification and quantification of Hypocretin-1/Orexin-A 1-14 and 1-16 fragments in immunopurified cerebrospinal fluid using LC-MS: Comparison with radioimmunoassay (RIA) determinations. Sleep Medicine. 2026;145:109006. doi:10.1016/j.sleep.2026.109006

BibTeX
@article{Maus2026,
  author = {Maus, Anthony and Figdore, Daniel and Chavan, Sandip and Ruoff, Chad and Krahn, Lois and Pandey, Akhilesh and Bornhorst, Joshua},
  title = {Identification and quantification of Hypocretin-1/Orexin-A 1-14 and 1-16 fragments in immunopurified cerebrospinal fluid using LC-MS: Comparison with radioimmunoassay (RIA) determinations},
  journal = {Sleep Medicine},
  year = {2026},
  volume = {145},
  pages = {109006},
  doi = {10.1016/j.sleep.2026.109006}
}
Kostenlos starten →