Assessment of simulated snoring sounds with artificial intelligence for the diagnosis of obstructive sleep apnea
Sleep Medicine · 2025-01 · 125 · 100-107
DOI: 10.1016/j.sleep.2024.11.018 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sleep Medicine, 2025-01. Verfasst von Lucheng Fang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan, Hubei, China; Department of Otorhinolaryngology, Head and Neck Surgery, Zhongnan Hosp…. Hauptthemen laut MEDLINE: Sleep Apnea, Obstructive, Snoring, Polysomnography, Artificial Intelligence. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Performing simulated snoring (SS) is a commonly used method to evaluate the source of snoring in obstructive sleep apnea (OSA). SS sounds is considered as a potential biomarker for OSA. SS sounds can be easily recorded, which is a cost-effective method for prescreening purposes. OBJECTIVE: This study aimed to validate the performance of artificial intelligence (AI) models using SS sounds for OSA diagnosis. METHODS: All participants underwent full-night polysomnography (PSG) monitoring at the sleep center. SS sounds of the participants were recorded during the laryngoscopy procedure. The audio data were processed via Python, and relevant features were extracted. OSA diagnostic models were developed using three machine learning (ML) algorithms and one deep learning (DL) algorithm. The diagnostic performance was evaluated by multiple indicators. RESULTS: A total of 465 participants were included. For the support vector machine algorithm, the accuracy values at apnea-hypopnea index (AHI) levels of 5, 15, and 30 per hour were 0.914, 0.887, and 0.807, respectively. For the K-nearest neighbor algorithm, the accuracy values at AHI levels of 5, 15, and 30 per hour were 0.896, 0.872, and 0.756, respectively. For the random forest algorithm, the accuracy values at AHI levels of 5, 15, and 30 per hour were 0.905, 0.881, and 0.804, respectively. For the audio spectrogram transformer algorithm, the accuracy values at AHI levels of 5, 15, and 30 per hour were 0.926, 0.887, and 0.830, respectively. CONCLUSIONS: Our study demonstrates that DL models can effectively screen and identify OSA with commendable performance. In addition, the identification ability of the DL models was better than that of any of the ML models.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan, Hubei, China; Department of Otorhinolaryngology, Head and Neck Surgery, Zhongnan Hospital of Wuhan University, Wuhan, Hubei, China; Sleep medicine centre,…
Zitieren
APA
Fang, L., Cai, J., Huang, Z., Tuohuti, A., & Chen, X. (2025). Assessment of simulated snoring sounds with artificial intelligence for the diagnosis of obstructive sleep apnea. Sleep Medicine, 125, 100-107. https://doi.org/10.1016/j.sleep.2024.11.018
Vancouver
Fang L, Cai J, Huang Z, Tuohuti A, Chen X. Assessment of simulated snoring sounds with artificial intelligence for the diagnosis of obstructive sleep apnea. Sleep Medicine. 2025;125:100-107. doi:10.1016/j.sleep.2024.11.018
BibTeX
@article{Fang2025,
author = {Fang, Lucheng and Cai, Jie and Huang, Zilin and Tuohuti, Aikebaier and Chen, Xiong},
title = {Assessment of simulated snoring sounds with artificial intelligence for the diagnosis of obstructive sleep apnea},
journal = {Sleep Medicine},
year = {2025},
volume = {125},
pages = {100--107},
doi = {10.1016/j.sleep.2024.11.018}
}
EUVIMED