Overcoming a false-positive mechanism in RapidFire MRM-based high throughput screening
SLAS Discovery · 2025
DOI: 10.1016/j.slasd.2025.100252 ↗Kurz gefasst
Fachartikel in der Zeitschrift SLAS Discovery, 2025. Verfasst von De Lin und 7 weiteren Autor:innen. Beteiligte Einrichtung: Drug Discovery Unit, School of Life Sciences, University of Dundee, Dundee, DD1 5EH, UK. Hauptthemen laut MEDLINE: High-Throughput Screening Assays, Drug Discovery, Mass Spectrometry. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bill & Melinda Gates Foundation, Wellcome Trust, Gates Foundation.
Abstract (Originalsprache)
False-positives plague high-throughput screening in general and are costly as they consume resource and time to resolve. Methods that can rapidly identify such compounds at the initial screen are therefore of great value. Advances in mass spectrometry have led to the ability to screen inhibitors in drug discovery applications by direct detection of an enzyme reaction product. The technique is free from some of the artefacts that trouble classical assays such as fluorescence interference. Its direct nature negates the need for coupling enzymes and hence is simpler with fewer opportunities for artefacts. Despite its myriad advantages, we report here a mechanism for false-positive hits which has not been reported in the literature. Further we have developed a pipeline for detecting these false-positive hits and suggest a method to mitigate against them.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Drug Discovery Unit, School of Life Sciences, University of Dundee, Dundee, DD1 5EH, UK.
- Drug Discovery Unit, School of Life Sciences, University of Dundee, Dundee, DD1 5EH, UK. Electronic address: i.h.gilbert@dundee.ac.uk.
Förderung
- Bill & Melinda Gates Foundation
- Wellcome Trust
- Gates Foundation
Zitieren
APA
Lin, Pearson, L. A., Ahmad, S., O'Neill, S., Post, J., Robinson, C., Scott, D. E., & Gilbert, I. H. (2025). Overcoming a false-positive mechanism in RapidFire MRM-based high throughput screening. SLAS Discovery. https://doi.org/10.1016/j.slasd.2025.100252
Vancouver
Lin, Pearson LA, Ahmad S, O'Neill S, Post J, Robinson C, et al. Overcoming a false-positive mechanism in RapidFire MRM-based high throughput screening. SLAS Discovery. 2025. doi:10.1016/j.slasd.2025.100252
BibTeX
@article{Lin2025,
author = {Lin, De and Pearson, Lesley-Anne and Ahmad, Shamshad and O'Neill, Sandra and Post, John and Robinson, Colin and Scott, Duncan E and Gilbert, Ian H},
title = {Overcoming a false-positive mechanism in RapidFire MRM-based high throughput screening},
journal = {SLAS Discovery},
year = {2025},
doi = {10.1016/j.slasd.2025.100252}
}
EUVIMED