EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 3.0

Effects of orthodontic miniscrew placement angle and structure on the stress distribution at the bone miniscrew interface – A 3D finite element analysis

Genevive L. Machado

The Saudi Journal for Dental Research · 2014

DOI: 10.1016/j.sjdr.2014.01.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Saudi Journal for Dental Research, 2014. Verfasst von Genevive L. Machado. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The study was conducted to evaluate the effects of orthodontic miniscrew placement angle and structure in terms of length and diameter on stress distribution at the bone miniscrew interface. 10 FE models were created representing miniscrews inserted in the buccal alveolar bone between the maxillary first molar and second premolar to simulate varying angulations of miniscrew placement (90°, 60°, 45°, 30°) to the long axis of the maxillary first molar, varying length (6mm, 8mm, 10mm, 12mm) and varying diameter (1.2mm, 1.3mm, 1.4mm, 1.5mm). In order to simulate retraction forces an identical force of 200 g was applied perpendicular to the long axis of the miniscrew in all the models. Finite Element Modeling Analysis was used to analyze the stress distribution at the bone miniscrew interface. Minimum and maximum stress in the miniscrew was generated at placement angles of 30° and 90° respectively. In the bone minimum and maximum stress was found at placement angles of 90° and 30° respectively. On increasing the miniscrew diameter stress in both the miniscrew and the bone decreased. There was no difference found in the stress distribution patterns with varying miniscrew length. Based on stress patterns, biomechanical stability of the miniscrew is enhanced by a placement angle of 90° to the long axis of the first maxillary molar and a diameter of 1.5 mm for the site selected in this study while miniscrew length has no implication on its stability.

Zitieren

APA

Machado, G. L. (2014). Effects of orthodontic miniscrew placement angle and structure on the stress distribution at the bone miniscrew interface – A 3D finite element analysis. The Saudi Journal for Dental Research. https://doi.org/10.1016/j.sjdr.2014.01.001

Vancouver

Machado GL. Effects of orthodontic miniscrew placement angle and structure on the stress distribution at the bone miniscrew interface – A 3D finite element analysis. The Saudi Journal for Dental Research. 2014. doi:10.1016/j.sjdr.2014.01.001

BibTeX
@article{Machado2014,
  author = {Machado, Genevive L.},
  title = {Effects of orthodontic miniscrew placement angle and structure on the stress distribution at the bone miniscrew interface – A 3D finite element analysis},
  journal = {The Saudi Journal for Dental Research},
  year = {2014},
  doi = {10.1016/j.sjdr.2014.01.001}
}
Kostenlos starten →