Exposure Assessment Study on Lithium-Ion Battery Fire in Explosion Test Room in Battery Testing Facility
Safety and Health at Work · 2024-03 · 15 (1) · 114-117
DOI: 10.1016/j.shaw.2023.11.007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Safety and Health at Work, 2024-03. Verfasst von Mi Sung Jo und 5 weiteren Autor:innen. Beteiligte Einrichtung: HCTm, Icheon, Republic of Korea. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
A lithium-ion battery is a rechargeable battery that uses the reversible reduction of lithium ions to store energy and is the predominant battery type in many industrial and consumer electronics. The lithium-ion batteries are essential to ensure they operate safely. We conducted an exposure assessment five days after a fire in a battery-testing facility. We assessed some of the potentially hazardous materials after a lithium-ion battery fire. We sampled total suspended particles, hydrogen fluoride, and lithium with real-time monitoring of particulate matter (PM) 1, 2.5, and 10 micrometers (μm). The area sampling results indicated that primary potential hazardous materials such as dust, hydrogen fluoride, and lithium were below the recommended limits suggested by the Korean Ministry of Labor and the American Conference of Governmental Industrial Hygienists Threshold Limit Values. Based on our assessment, workers were allowed to return to work.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- HCTm, Icheon, Republic of Korea.
- H&H Bio, Asan, Republic of Korea.
- Korea Industrial Association, Seoul, Republic of Korea.
- Intertox, Inc, Seattle, USA.
- Department of Environmental and Occupational Health Sciences, University of Washington, Seattle, WA, USA.
- HCT, Seattle, USA.
Zitieren
APA
Jo, M. S., Kim, H. P., Kim, B. W., Pleus, R. C., Faustman, E. M., & Yu, I. J. (2024). Exposure Assessment Study on Lithium-Ion Battery Fire in Explosion Test Room in Battery Testing Facility. Safety and Health at Work, 15(1), 114-117. https://doi.org/10.1016/j.shaw.2023.11.007
Vancouver
Jo MS, Kim HP, Kim BW, Pleus RC, Faustman EM, Yu IJ. Exposure Assessment Study on Lithium-Ion Battery Fire in Explosion Test Room in Battery Testing Facility. Safety and Health at Work. 2024;15(1):114-117. doi:10.1016/j.shaw.2023.11.007
BibTeX
@article{Jo2024,
author = {Jo, Mi Sung and Kim, Hoi Pin and Kim, Boo Wook and Pleus, Richard C and Faustman, Elaine M and Yu, Il Je},
title = {Exposure Assessment Study on Lithium-Ion Battery Fire in Explosion Test Room in Battery Testing Facility},
journal = {Safety and Health at Work},
year = {2024},
volume = {15},
number = {1},
pages = {114--117},
doi = {10.1016/j.shaw.2023.11.007}
}