Kurz gefasst

Fachartikel in der Zeitschrift Science of The Total Environment, 2024. Verfasst von Anjishnu Biswas und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil Engineering, Indian Institute of Technology Guwahati, Guwahati 781039, India. Electronic address: anjishnu18@iitg.ac.in. Hauptthemen laut MEDLINE: Wastewater, Bioelectric Energy Sources. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 62 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The current study is focused on understanding the operational mechanism of an integrated constructed wetland-microbial fuel cell (CW-MFC) reactor emphasizing fecal coliform (FC) removal. Few studies are available in the literature investigating the inherent mechanisms of pathogen inactivation in a CW-MFC system. Raw domestic wastewater was treated in three vertical reactors, one planted constructed wetland (R1), one planted CW-MFC (R2), and one unplanted CW-MFC (R3). Spatial analysis of treated effluents showed a considerable amount of organics and fecal coliform removal at the vicinity of the anode in R2. Assessment of the microbial population inside all the reactors revealed that EABs (Firmicutes, Bacteroidetes, and Actinobacteria) were more abundant in R2 compared to R1 and R3. During the activity study, biomass obtained from R2 showed a maximum substrate utilization rate of 1.27 mg COD mgVSS-1 d-1. Kinetic batch studies were carried out for FC removal in all the reactors, and the maximum first order FC removal rate was obtained at the anode of R2 as 2.13 d-1 when operated in closed circuit mode. This value was much higher than the natural die-off rate of FCs in raw wastewater which was 1.16 d-1. Simultaneous bioelectricity monitoring inferred that voltage generation can be correlated to faster FC inactivation, which was probably due to EABs outcompeting other exogenous microbes in a preferable anaerobic environment with the presence of an anode. Reactor R2 was found to be functioning as a symbiotic bio-electrochemical mesocosm.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WastewaterBioelectric Energy SourcesGram-Negative BacteriaBacteriaWetlandsElectrodesElectricity

Stichwörter der Autor:innen

Bioelectrochemical mesocosmCW-MFCElectroactive bacteriaFecal coliformsMicrobial metagenomics

Substanzen

Wastewater

Autor:innen und Institutionen

  • Department of Civil Engineering, Indian Institute of Technology Guwahati, Guwahati 781039, India. Electronic address: anjishnu18@iitg.ac.in.
  • Department of Civil Engineering, Indian Institute of Technology Guwahati, Guwahati 781039, India. Electronic address: saswati@iitg.ac.in.

Zitieren

APA

Biswas, A., & Chakraborty, S. (2024). Assessment of microbial population in integrated CW-MFC system and investigation of organics and fecal coliform removal pathway. Science of The Total Environment. https://doi.org/10.1016/j.scitotenv.2023.168809

Vancouver

Biswas A, Chakraborty S. Assessment of microbial population in integrated CW-MFC system and investigation of organics and fecal coliform removal pathway. Science of The Total Environment. 2024. doi:10.1016/j.scitotenv.2023.168809

BibTeX
@article{Biswas2024,
  author = {Biswas, Anjishnu and Chakraborty, Saswati},
  title = {Assessment of microbial population in integrated CW-MFC system and investigation of organics and fecal coliform removal pathway},
  journal = {Science of The Total Environment},
  year = {2024},
  doi = {10.1016/j.scitotenv.2023.168809}
}
Kostenlos starten →