EUVIMEDEUVIMED entdecken
Crossref

T-shaped confined microplasma system for rapid colorimetric detection of Cr(VI)

Yali Gong, Qiang Chen, Yi Cai, Yong Zhao

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2027-03 · 368 · 129106

DOI: 10.1016/j.saa.2026.129106 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2027-03. Verfasst von Yali Gong und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Intelligent Sensing and Optoelectronic Engineering, Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology…. Die Arbeit nennt 49 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microplasma technology enables miniaturized chemical sensing; however, its detection performance is constrained by poor energy coupling and inefficient gas-liquid mass transfer, which reduce sensitivity and response speed. Herein, a miniaturized colorimetric detection system based on a T-shaped confined microplasma reactor is presented to address these challenges. Quartz tubes were employed to achieve strong geometric confinement, effectively suppressing radial diffusion of the microplasma and thereby enhancing collision frequency and excitation efficiency of reactive species at the gas-liquid interface. With Cr(VI) present in the system, the reactive oxygen species (ROS) produced by the microplasma markedly accelerate the oxidation of 2,2'-Azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt (ABTS), completing the colorimetric reaction in seconds rather than minutes, as evidenced by a rapid visual transition from colorless to blue-green. Under optimized conditions, the system exhibits excellent linearity over the range of 3-50 μmol L-1, with a limit of detection (LOD) as low as 0.91 μmol L-1. The system's practical applicability was validated by real water sample analysis, with satisfactory recoveries. The miniaturized design and rapid analytical response suggest potential for on-site Cr(VI) analysis in environmental monitoring.

Schlagwörter

Stichwörter der Autor:innen

Colorimetric detectionHexavalent chromiumMicroplasmaOn-site monitoringSpatial confinement

Autor:innen und Institutionen

  • School of Intelligent Sensing and Optoelectronic Engineering, Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China.
  • School of Intelligent Sensing and Optoelectronic Engineering, Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China. E…
  • School of Intelligent Sensing and Optoelectronic Engineering, Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China; C…

Zitieren

APA

Gong, Y., Chen, Q., Cai, Y., & Zhao, Y. (2027). T-shaped confined microplasma system for rapid colorimetric detection of Cr(VI). Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 368, 129106. https://doi.org/10.1016/j.saa.2026.129106

Vancouver

Gong Y, Chen Q, Cai Y, Zhao Y. T-shaped confined microplasma system for rapid colorimetric detection of Cr(VI). Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2027;368:129106. doi:10.1016/j.saa.2026.129106

BibTeX
@article{Gong2027,
  author = {Gong, Yali and Chen, Qiang and Cai, Yi and Zhao, Yong},
  title = {T-shaped confined microplasma system for rapid colorimetric detection of Cr(VI)},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2027},
  volume = {368},
  pages = {129106},
  doi = {10.1016/j.saa.2026.129106}
}
Kostenlos starten →