EUVIMEDEUVIMED entdecken
Crossref

Machine learning-assisted optimization of a BK7/Ag/As₂S₃/graphene surface plasmon resonance biosensor for high-sensitivity urine glucose detection

U Arun Kumar, A Alavudeen Basha, Hashim Elshafie, Azath Mubarakali, P Parthasarathy, Ngaira Mandela

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2027

DOI: 10.1016/j.saa.2026.128775 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2027. Verfasst von U Arun Kumar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Electronics Engineering, Faculty of Engineering, Karpagam Academy of Higher Education (Deemed to be University), Coimbat…. Hauptthemen laut MEDLINE: Surface Plasmon Resonance, Graphite, Machine Learning, Biosensing Techniques. Die Arbeit nennt 58 Literaturangaben. Gefördert von: King Khalid University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Blood glucose monitoring remains challenging due to the invasiveness of finger-prick methods, enzyme instability in electrochemical sensors, and the limitations of laboratory-based techniques for continuous real-time detection. This study presents a theoretically optimized multilayer surface plasmon resonance (SPR) biosensor based on a BK7 prism/silver/arsenic trisulfide/graphene structure operating at 633 nm for non-invasive glucose detection in urine. The novelty of the proposed approach lies in the integration of an ultrathin As₂S₃ dielectric spacer and graphene sensing layer with a systematic electromagnetic optimization and Gradient Boosting Regressor (GBR)-based predictive framework within a single SPR sensing platform. Using the transfer matrix method and electromagnetic field analysis, the optimized thicknesses were identified as 52 nm for silver, 1.0 nm for arsenic trisulfide, and 1.32 nm for graphene, enabling strong plasmonic coupling and enhanced sensing performance. The proposed sensor achieved sensitivities ranging from 33.333 to 500°/RIU, a maximum figure of merit of 555.556 RIU-1, and a detection limit of 0.001 RIU over a refractive index range of 1.335-1.347. Furthermore, the combination of multilayer optical optimization with GBR-based surrogate modelling provides an efficient approach for predicting the resonance response across the investigated design space and reducing the need for repeated electromagnetic simulations. Machine learning validation using a Gradient Boosting Regressor achieved R2 values above 0.99, confirming the robustness and reliability of the proposed biosensor design.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surface Plasmon ResonanceGraphiteMachine LearningBiosensing TechniquesGlucoseHumansSilverLimit of DetectionBoosting Machine Learning Algorithms

Stichwörter der Autor:innen

Diabetes managementDiabetes screening and early detectionGlucose biosensorMachine learningRefractive index sensingSurface plasmon resonance

Substanzen

GraphiteSilverGlucose

Autor:innen und Institutionen

  • Department of Electrical and Electronics Engineering, Faculty of Engineering, Karpagam Academy of Higher Education (Deemed to be University), Coimbatore 641021, Tamil Nadu, India; Centre for Energy and Environment, Karp…
  • Department of Biomedical Engineering, Excel Engineering College, Namakkal, Tamilnadu, India.
  • Department of Computer Engineering, College of Computer Science, King Khalid University, Main Campus Al Farah, Abha 61421, Saudi Arabia. Electronic address: helshafie@kku.edu.sa.
  • Department of Informatics and Computer Systems, College of Computer Science, King Khalid University, Abha, Saudi Arabia. Electronic address: aabdurrahman@kku.edu.sa.
  • Department of ECE, CMR Institute of Technology, Bengaluru 560037, Karnataka, India. Electronic address: parthasarathy.p@cmrit.ac.in.
  • School of Science and Technology, Open University of Kenya, The Cradle, Silicon Savanna, Konza Technopolis, P. O. Box 2440, Nairobi, Kenya.

Förderung

  • King Khalid University

Zitieren

APA

Arun Kumar, U., Alavudeen Basha, A., Elshafie, H., Mubarakali, A., Parthasarathy, P., & Mandela, N. (2027). Machine learning-assisted optimization of a BK7/Ag/As₂S₃/graphene surface plasmon resonance biosensor for high-sensitivity urine glucose detection. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2026.128775

Vancouver

Arun Kumar U, Alavudeen Basha A, Elshafie H, Mubarakali A, Parthasarathy P, Mandela N. Machine learning-assisted optimization of a BK7/Ag/As₂S₃/graphene surface plasmon resonance biosensor for high-sensitivity urine glucose detection. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2027. doi:10.1016/j.saa.2026.128775

BibTeX
@article{ArunKumar2027,
  author = {Arun Kumar, U and Alavudeen Basha, A and Elshafie, Hashim and Mubarakali, Azath and Parthasarathy, P and Mandela, Ngaira},
  title = {Machine learning-assisted optimization of a BK7/Ag/As₂S₃/graphene surface plasmon resonance biosensor for high-sensitivity urine glucose detection},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2027},
  doi = {10.1016/j.saa.2026.128775}
}
Kostenlos starten →