EUVIMEDEUVIMED entdecken
Crossref

Pu(IV) quantification via visible–near-infrared absorption spectroscopy: tackling interferences using D-optimal design and partial least squares

Luke R Sadergaski, Jeffrey D Einkauf, Sara E Gilson, Laetitia H Delmau, Jonathan D Burns

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2026-12 · 363 · 128411

DOI: 10.1016/j.saa.2026.128411 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2026-12. Verfasst von Luke R Sadergaski und 4 weiteren Autor:innen. Beteiligte Einrichtung: Oak Ridge National Laboratory, Oak Ridge, TN, USA. Electronic address: sadergaskilr@ornl.gov. Die Arbeit nennt 44 Literaturangaben. Gefördert von: Oak Ridge National Laboratory, Advanced Research Projects Agency - Energy, U.S. Department of Energy.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents a novel analytical approach for quantifying Pu(IV) in glove box environments using fiber-optic-based visible-near-infrared absorption spectroscopy in combination with partial least squares regression (PLSR) and design of experiments. The method addresses significant challenges posed by overlapping spectral features arising from Nd(III), which is a common fission product impurity, and the speciation variability of Pu(IV) nitrato complexes in HNO3 concentrations ranging from 2.5 to 11 M. A curated training set consisting of data from 20 samples was developed via D-optimal design to enable robust PLSR model calibration for Pu(IV) using the near-infrared band near 1050 nm. The training set was acquired from samples in cuvettes with a 1-cm path length and was used to build the PLSR model. The robustness of the model was validated with data collected using a dip probe with a 1-cm path length and varying Pu(IV) concentrations. The strong performance of the model indicates good model transfer from cuvette to dip probe and highlights the potential for in situ measurements and online monitoring of reactions in a crystallization reactor vessel. The results demonstrate that this combined spectroscopic and chemometric approach can accurately and simultaneously quantify Pu(IV) and HNO3, thereby offering a promising tool for real-time monitoring in process environments.

Schlagwörter

Stichwörter der Autor:innen

ActinideChemometricsMultivariate analysisOptical spectroscopyplutonium

Autor:innen und Institutionen

  • Oak Ridge National Laboratory, Oak Ridge, TN, USA. Electronic address: sadergaskilr@ornl.gov.
  • Oak Ridge National Laboratory, Oak Ridge, TN, USA.
  • Department of Chemistry, University of Alabama at Birmingham, Birmingham, AL, USA. Electronic address: burnsjon@uab.edu.

Förderung

  • Oak Ridge National Laboratory
  • Advanced Research Projects Agency - Energy
  • U.S. Department of Energy

Zitieren

APA

Sadergaski, L. R., Einkauf, J. D., Gilson, S. E., Delmau, L. H., & Burns, J. D. (2026). Pu(IV) quantification via visible–near-infrared absorption spectroscopy: tackling interferences using D-optimal design and partial least squares. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 363, 128411. https://doi.org/10.1016/j.saa.2026.128411

Vancouver

Sadergaski LR, Einkauf JD, Gilson SE, Delmau LH, Burns JD. Pu(IV) quantification via visible–near-infrared absorption spectroscopy: tackling interferences using D-optimal design and partial least squares. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2026;363:128411. doi:10.1016/j.saa.2026.128411

BibTeX
@article{Sadergaski2026,
  author = {Sadergaski, Luke R and Einkauf, Jeffrey D and Gilson, Sara E and Delmau, Laetitia H and Burns, Jonathan D},
  title = {Pu(IV) quantification via visible–near-infrared absorption spectroscopy: tackling interferences using D-optimal design and partial least squares},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2026},
  volume = {363},
  pages = {128411},
  doi = {10.1016/j.saa.2026.128411}
}
Kostenlos starten →