Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2026-12. Verfasst von Yilong Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China. Hauptthemen laut MEDLINE: Biosensing Techniques, Fluorescence Resonance Energy Transfer, Keratin-19, Antigens, Neoplasm. Die Arbeit nennt 40 Literaturangaben. Gefördert von: China Postdoctoral Science Foundation.
Abstract (Originalsprache)
The rapid and sensitive detection of cytokeratin 19 fragment (CYFRA21-1) is essential for the early screening and diagnosis of lung cancer. Herein, we developed a novel fluorescence resonance energy transfer (FRET) biosensor based on upconversion nanoparticles (UCNPs), incorporating an atom transfer radical polymerization (ATRP) signal amplification strategy for the rapid and sensitive detection of CYFRA21-1. The FRET biosensor employs UCNPs, which exhibit a low biological background signal and high quantum yield, as the energy donor, and gold nanoparticles (AuNPs) as the energy acceptor. The distance between the energy donor and acceptor is reduced through specific antigen/antibody interactions, leading to the quenching of the donor luminescence signal. The grafting of UCNPs on specific antibodies via ATRP can significantly enhance the quenching of fluorescence signal, thus improving the detection sensitivity. Under optimal conditions, the biosensor demonstrated a linear range of 1 ng/mL ∼ 60 ng/mL with a detection limit of 0.66 ng/mL. Furthermore, the biosensor exhibited high accuracy, selectivity, and robust anti-interference capabilities in the presence of complex biological matrices. This versatile sensing platform can be readily adapted for various targets, holding great promise for applications in medical diagnostics, environmental monitoring, and food safety.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China.
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China. Electronic address: yanghuaixia886@163.com.
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China. Electronic address: zhiy_l@163.com.
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China. Electronic address: liuyanju886@163.com.
Förderung
- China Postdoctoral Science Foundation
Zitieren
APA
Wang, Y., Wang, Z., Zhao, L., Hou, M., Yang, H., Zhi, Y., & Liu, Y. (2026). An upconversion FRET biosensor using ATRP-grafted polymer brushes as a signal amplifier for ultrasensitive detection of CYFRA21-1. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 363, 128312. https://doi.org/10.1016/j.saa.2026.128312
Vancouver
Wang Y, Wang Z, Zhao L, Hou M, Yang H, Zhi Y, et al. An upconversion FRET biosensor using ATRP-grafted polymer brushes as a signal amplifier for ultrasensitive detection of CYFRA21-1. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2026;363:128312. doi:10.1016/j.saa.2026.128312
BibTeX
@article{Wang2026,
author = {Wang, Yilong and Wang, Zhendong and Zhao, Liying and Hou, Mengyuan and Yang, Huaixia and Zhi, Yanle and Liu, Yanju},
title = {An upconversion FRET biosensor using ATRP-grafted polymer brushes as a signal amplifier for ultrasensitive detection of CYFRA21-1},
journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
year = {2026},
volume = {363},
pages = {128312},
doi = {10.1016/j.saa.2026.128312}
}
EUVIMED