EUVIMEDEUVIMED entdecken
Crossref

A portable smartphone-assisted fluorescent probe for the visualization and quantitative detection of ferric ions in aqueous solutions

Yunkai Zhang, Jingqi Wang, Yifan Zhang, Sihao Wang, Siting Peng, Qiao Jin, Enqi Wei, Da Chen

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2026-12 · 363 · 128302

DOI: 10.1016/j.saa.2026.128302 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2026-12. Verfasst von Yunkai Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Maritime and Transportation, Ningbo University, Ningbo 315211, PR China; Department of Microelectronic Science and Engineering, School of …. Die Arbeit nennt 48 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate monitoring of ferric ions (Fe3+) in aquatic environments is essential, as elevated concentrations pose serious risks to human health and ecosystems. Herein, a fluorescent sensor based on blue-emissive carbon dots (B-CDs) has been developed for the detection of Fe3+ in aqueous solutions. The B-CDs are prepared through a one-step solvothermal method using 5-aminoisophthalic acid and phloroglucinol as precursors and exhibit intense blue fluorescence. Upon the addition of Fe3+, the fluorescence of the B-CDs is significantly quenched due to the combined effects of the inner filter effect (IFE) and static quenching mechanism, enabling Fe3+ detection with a limit of detection (LOD) of 92 nM over a linear range of 0.092-70 μM. In addition, a smartphone-integrated sensing system is constructed by immobilizing the B-CDs onto filter paper, facilitating on-site visual quantification of Fe3+ with a LOD of 176 nM. Furthermore, the sensor exhibits recovery rates ranging from 97.5% to 103.8%, with relative standard deviations (RSDs) below 3.42%. These findings confirm the reliability and high accuracy of the proposed paper-based sensing platform for Fe3+ detection in real samples. These results demonstrate that this portable and cost-effective sensing system offers an accurate and practical approach for Fe3+ monitoring, with promising applications in health protection and environmental surveillance.

Schlagwörter

Stichwörter der Autor:innen

Carbon dotsFerric ionsInner filter effectSmartphone-assisted sensing systemStatic quenching effectVisual detection

Autor:innen und Institutionen

  • Faculty of Maritime and Transportation, Ningbo University, Ningbo 315211, PR China; Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, PR…
  • Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, PR China.
  • Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, PR China. Electronic address: chenda@nbu.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, Y., Wang, J., Zhang, Y., Wang, S., Peng, S., Jin, Q., Wei, E., & Chen, D. (2026). A portable smartphone-assisted fluorescent probe for the visualization and quantitative detection of ferric ions in aqueous solutions. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 363, 128302. https://doi.org/10.1016/j.saa.2026.128302

Vancouver

Zhang Y, Wang J, Zhang Y, Wang S, Peng S, Jin Q, et al. A portable smartphone-assisted fluorescent probe for the visualization and quantitative detection of ferric ions in aqueous solutions. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2026;363:128302. doi:10.1016/j.saa.2026.128302

BibTeX
@article{Zhang2026,
  author = {Zhang, Yunkai and Wang, Jingqi and Zhang, Yifan and Wang, Sihao and Peng, Siting and Jin, Qiao and Wei, Enqi and Chen, Da},
  title = {A portable smartphone-assisted fluorescent probe for the visualization and quantitative detection of ferric ions in aqueous solutions},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2026},
  volume = {363},
  pages = {128302},
  doi = {10.1016/j.saa.2026.128302}
}
Kostenlos starten →