Rational design of a water-soluble chemodosimeter for highly selective cyanide detection
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2026-12 · 363 · 128295
DOI: 10.1016/j.saa.2026.128295 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2026-12. Verfasst von Li-Ching Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Feng Chia University, 40724 Taichung, Taiwan, ROC. Die Arbeit nennt 118 Literaturangaben. Gefördert von: National Science and Technology Council.
Abstract (Originalsprache)
A low-molecular-weight polyethylene glycol (PEG)-modified aniline-indandione conjugate (AI) chemodosimeter was synthesized and compared with its dimethylaniline-indandione precursor. Although the synthesized PEGylated chemodosimeter is highly water soluble, it maintains a high fluorescence quantum yield in the neat film state. When exposed to cyanide in aqueous and solid states, AI exhibits significant changes in color and fluorescence owing to nucleophilic addition, effectively inhibiting the intramolecular charge transfer process. The limit of detection of cyanide by AI is 2.3 × 10-7 M, aligning with other established cyanide-selective sensors and significantly lower than the World Health Organization's recommended limit of 1.9 × 10-6 M. We developed simple and affordable paper-based test strips embedding AI, facilitating fast, quantitative, and on-site cyanide detection, visible through color changes and fluorescence. This study demonstrates a practical molecular design strategy for developing water-soluble chemodosimeters tailored for selective cyanide detection.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemical Engineering, Feng Chia University, 40724 Taichung, Taiwan, ROC.
- Department of Medical Applied Chemistry, Chung Shan Medical University, 40201 Taichung, Taiwan, ROC; Department of Medical Education, Chung Shan Medical University Hospital, 40201 Taichung, Taiwan, ROC. Electronic addre…
- Department of Chemical Engineering, Feng Chia University, 40724 Taichung, Taiwan, ROC. Electronic address: kyuchen@fcu.edu.tw.
Förderung
- National Science and Technology Council
Zitieren
APA
Wang, L. C., Hu, J. W., Chiu, W. C., Liu, K. M., & Chen, K. Y. (2026). Rational design of a water-soluble chemodosimeter for highly selective cyanide detection. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 363, 128295. https://doi.org/10.1016/j.saa.2026.128295
Vancouver
Wang LC, Hu JW, Chiu WC, Liu KM, Chen KY. Rational design of a water-soluble chemodosimeter for highly selective cyanide detection. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2026;363:128295. doi:10.1016/j.saa.2026.128295
BibTeX
@article{Wang2026,
author = {Wang, Li-Ching and Hu, Jiun-Wei and Chiu, Wei-Chieh and Liu, Kuan-Miao and Chen, Kew-Yu},
title = {Rational design of a water-soluble chemodosimeter for highly selective cyanide detection},
journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
year = {2026},
volume = {363},
pages = {128295},
doi = {10.1016/j.saa.2026.128295}
}
EUVIMED