Measurement of gas phase naphthalene with deep-UV broadband cavity-enhanced and integrated absorption spectroscopy
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2026-10 · 359 · 127964
DOI: 10.1016/j.saa.2026.127964 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2026-10. Verfasst von Zhenghao Chen und 3 weiteren Autor:innen. Beteiligte Einrichtung: China Machinery Industry Federation Key Laboratory of Multiphase Flow Measurement, School of Energy and Power Engineering, University of Shanghai for…. Die Arbeit nennt 28 Literaturangaben. Gefördert von: Science Foundation Ireland.
Abstract (Originalsprache)
Naphthalene, a representative semi-volatile organic compound (SVOC), poses significant challenges for optical quantification due to surface adsorption and the difficulty of generating stable standards. To address these issues, a deep-ultraviolet Incoherent Broadband Cavity-Enhanced Absorption Spectroscopy (IBBCEAS) system (mirror reflectivity >99.25%, 245-275 nm) was developed. The system achieved a detection limit of 1.3 × 10-7 cm-1 A dual-mode sampling strategy was employed to validate quantitative performance. First, steady-state saturation transpiration measurements yielded naphthalene absorption cross sections that agreed excellently with high-resolution literature data which validated the system. Second, an Integrated Absorption Spectroscopy (IAS) strategy was implemented to quantify transient pulse injections. The method demonstrated a strict linearity (R2 ≈ 0.99) between the flow integrated optical signal and injected mass. Crucially, the physical validity of the IAS framework was rigorously supported by varying the carrier gas flow rate: a slope ratio of ≈2.0 was observed when the flow rate was halved, consistent with the principle of mass conservation. This work demonstrates that the IBBCEAS-IAS framework effectively mitigates quantification errors caused by adsorption desorption hysteresis. Furthermore, the proven capability for measuring transient pulses highlights the method's potential for coupling with preconcentration desorption techniques (e.g., adsorbent tubes or cold traps) to accurately quantify the total concentration of sticky SVOCs.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- China Machinery Industry Federation Key Laboratory of Multiphase Flow Measurement, School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
- China Machinery Industry Federation Key Laboratory of Multiphase Flow Measurement, School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.; Department of Chemis…
- Department of Chemistry and Sustainability Institute, University College Cork, Cork, Ireland.
- China Machinery Industry Federation Key Laboratory of Multiphase Flow Measurement, School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.. Electronic address:…
Förderung
- Science Foundation Ireland
Zitieren
APA
Chen, Z., Wang, M., Venables, D. S., & Chen, J. (2026). Measurement of gas phase naphthalene with deep-UV broadband cavity-enhanced and integrated absorption spectroscopy. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 359, 127964. https://doi.org/10.1016/j.saa.2026.127964
Vancouver
Chen Z, Wang M, Venables DS, Chen J. Measurement of gas phase naphthalene with deep-UV broadband cavity-enhanced and integrated absorption spectroscopy. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2026;359:127964. doi:10.1016/j.saa.2026.127964
BibTeX
@article{Chen2026,
author = {Chen, Zhenghao and Wang, Meng and Venables, Dean S and Chen, Jun},
title = {Measurement of gas phase naphthalene with deep-UV broadband cavity-enhanced and integrated absorption spectroscopy},
journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
year = {2026},
volume = {359},
pages = {127964},
doi = {10.1016/j.saa.2026.127964}
}
EUVIMED