EUVIMEDEUVIMED entdecken
Crossref

A multilayer 2D material plasmonic metasurface terahertz biosensor with machine learning optimization for high-sensitivity tuberculosis detection

Abdulkarem H M Almawgani, Sultan Alkhteeb, Abdulrhman Alshaabani, Jacob Wekalao, Affaq Qamar, Amuthakkannan Rajakannu

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2026-10 · 358 · 127847

DOI: 10.1016/j.saa.2026.127847 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2026-10. Verfasst von Abdulkarem H M Almawgani und 5 weiteren Autor:innen. Beteiligte Einrichtung: Electrical Engineering Department, College of Engineering, Najran University, Najran, Saudi Arabia. Electronic address: ahalmawgani@nu.edu.sa. Hauptthemen laut MEDLINE: Biosensing Techniques, Machine Learning, Tuberculosis, Terahertz Spectroscopy. Die Arbeit nennt 77 Literaturangaben. Gefördert von: Deanship of Scientific Research, Imam Mohammed Ibn Saud Islamic University, Imam Mohammed Ibn Saud Islamic University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Tuberculosis (TB) remains a leading global infectious disease, with over 10.6 million new cases annually and persistent diagnostic gaps in low-resource settings. Existing methods such as sputum smear microscopy and nucleic acid amplification tests suffer from low sensitivity, long turnaround times, and infrastructure dependency. To address these shortcomings, this work proposes a novel five-layer Au/Graphene/MoS₂/MXene/Phosphorene/WS₂ plasmonic metasurface terahertz (THz) biosensor for label-free, high-sensitivity TB biomarker detection. The hierarchical architecture integrates a MXene-functionalized elliptical central resonator for selective TB biomarker capture (LAM and MPT64 antigen), concentric Au/phosphorene ring resonators for polarization-dependent field enhancement, peripheral WS₂ and MoS₂ resonators for multiband absorption and chemical stability, and a gate-tunable graphene layer enabling dynamic post-fabrication tunability. Finite-element electromagnetic simulations and the transfer matrix method were employed to characterize the full spectral and near-field response. Bayesian Ridge regression was applied to optimize geometric parameters, resonator dimensions, and incidence angles, achieving predictive R2 values exceeding 0.9996. The optimized sensor delivers a maximum sensitivity of 1000 GHz/RIU, a figure of merit of 30.303 RIU-1, an electric field enhancement of 1.1 × 108 V/m at resonance (0.996 THz), and off-resonance transmittance consistently above 98% across graphene chemical potentials from 0.1 to 0.9 eV and incidence angles from 0° to 80°. These results establish the proposed sensor as a competitive platform for rapid, accurate, point-of-care TB diagnostics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesMachine LearningTuberculosisTerahertz SpectroscopyHumansGraphiteGold

Stichwörter der Autor:innen

2D materialsMachinePlasmonic metasurfaceTerahertz biosensingTuberculosis detection

Substanzen

GraphiteGold

Autor:innen und Institutionen

  • Electrical Engineering Department, College of Engineering, Najran University, Najran, Saudi Arabia. Electronic address: ahalmawgani@nu.edu.sa.
  • Department of Electrical Engineering, College of Engineering, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11432, Saudi Arabia.
  • Department of Electrical Engineering, College of Engineering, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11432, Saudi Arabia. Electronic address: alalshaabani@imamu.edu.sa.
  • Department of Optics and Optical Engineering, University of Science and Technology of China, Hefei 230026, China. Electronic address: jacob.phdfs2303@nfsu.ac.in.
  • Department of Electrical Engineering, College of Engineering, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11432, Saudi Arabia. Electronic address: aaqamar@imamu.edu.sa.
  • Department of Mechanical and Industrial Engineering, College of Engineering, National University of Science and Technology, Muscat, Sultanate of Oman. Electronic address: amuthakkannan@nu.edu.om.

Förderung

  • Deanship of Scientific Research, Imam Mohammed Ibn Saud Islamic University
  • Imam Mohammed Ibn Saud Islamic University

Zitieren

APA

Almawgani, A. H. M., Alkhteeb, S., Alshaabani, A., Wekalao, J., Qamar, A., & Rajakannu, A. (2026). A multilayer 2D material plasmonic metasurface terahertz biosensor with machine learning optimization for high-sensitivity tuberculosis detection. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 358, 127847. https://doi.org/10.1016/j.saa.2026.127847

Vancouver

Almawgani AHM, Alkhteeb S, Alshaabani A, Wekalao J, Qamar A, Rajakannu A. A multilayer 2D material plasmonic metasurface terahertz biosensor with machine learning optimization for high-sensitivity tuberculosis detection. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2026;358:127847. doi:10.1016/j.saa.2026.127847

BibTeX
@article{Almawgani2026,
  author = {Almawgani, Abdulkarem H M and Alkhteeb, Sultan and Alshaabani, Abdulrhman and Wekalao, Jacob and Qamar, Affaq and Rajakannu, Amuthakkannan},
  title = {A multilayer 2D material plasmonic metasurface terahertz biosensor with machine learning optimization for high-sensitivity tuberculosis detection},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2026},
  volume = {358},
  pages = {127847},
  doi = {10.1016/j.saa.2026.127847}
}
Kostenlos starten →