Synthesis of fluorescent iron-doped carbon dots with Fenton activity for noninvasive dual-mode urinary uric acid monitoring toward point-of-care renal diagnostics
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2026
DOI: 10.1016/j.saa.2026.127709 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2026. Verfasst von Shaimaa Abubakr Abdalla und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, College of Science, University of Sulaimani, Qliasan Street, Sulaymaniyah 46002, Kurdistan Region, Iraq. Hauptthemen laut MEDLINE: Uric Acid, Carbon Quantum Dots, Hydrogen Peroxide, Iron. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 93 Literaturangaben.
Abstract (Originalsprache)
Rapid, selective and point-of-care urinary uric acid (UA) monitoring is important for managing renal and metabolic disorders. This study employed solvothermal synthesis of fluorescent iron-doped carbon dots (Fe-CDs) exhibiting a fluorescence quantum yield of 44.5%. Pronounced fluorescence quenching of Fe-CDs was observed upon the introduction of hydrogen peroxide (H₂O₂), attributable to a Fenton reaction-based mechanism. In contrast, non-doped CDs exhibited no fluorescence quenching in the presence of H₂O₂, confirming the essential role of iron doping in the quenching process. The uricase-catalyzed oxidation of UA generates H₂O₂, enabling a turn-off sensing approach for UA that can be quantified using both smartphone-based colorimetric and spectrofluorometric analysis. This strategy confers high selectivity, effectively mitigating matrix interference from biological fluids. The smartphone-based visual assay achieved a limit of detection (LOD) of 1.67 μM (linear range: 5-600 μM), whereas the instrument-based fluorometric analysis yielded a superior LOD of 0.78 μM (linear range: 3-1000 μM). The assay effectively encompassed clinically relevant urinary UA concentrations, with spiked urine sample recoveries ranging from 95.5-105.6% and 95.0-105.7% for the fluorimeteric and the smartphone-mode, respectively. Statistical analysis of real urine samples demonstrated error percentages within ±2%. Paired t-test values of 2.053 and 0.509 were obtained for the fluorometric and smartphone-based modes, respectively, indicating no significant differences compared with the reference colorimetric enzymatic assay at the 95% and 99% confidence levels. Additionally, non-significant F-test results at both confidence levels confirmed the high accuracy, precision, and reliability of the proposed methods. Collectively, these findings highlight Fe-CDs as a versatile and practical platform for point-of-care detection of uric acid in clinical diagnostics, further underscored by their intrinsic catalytic oxidation of H₂O₂ via the Fenton reaction mechanism.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, College of Science, University of Sulaimani, Qliasan Street, Sulaymaniyah 46002, Kurdistan Region, Iraq.
- Department of Chemistry, College of Science, University of Sulaimani, Qliasan Street, Sulaymaniyah 46002, Kurdistan Region, Iraq. Electronic address: khalid.omer@univsul.edu.iq.
Zitieren
APA
Abdalla, S. A., & Omer, K. M. (2026). Synthesis of fluorescent iron-doped carbon dots with Fenton activity for noninvasive dual-mode urinary uric acid monitoring toward point-of-care renal diagnostics. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2026.127709
Vancouver
Abdalla SA, Omer KM. Synthesis of fluorescent iron-doped carbon dots with Fenton activity for noninvasive dual-mode urinary uric acid monitoring toward point-of-care renal diagnostics. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2026. doi:10.1016/j.saa.2026.127709
BibTeX
@article{Abdalla2026,
author = {Abdalla, Shaimaa Abubakr and Omer, Khalid M},
title = {Synthesis of fluorescent iron-doped carbon dots with Fenton activity for noninvasive dual-mode urinary uric acid monitoring toward point-of-care renal diagnostics},
journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
year = {2026},
doi = {10.1016/j.saa.2026.127709}
}
EUVIMED