EUVIMEDEUVIMED entdecken
Vergleichsstudie

Quantitative determination of submerged oil concentrations by time-resolved fluorescence spectroscopy: A comparison of multi-way calibration strategies

Zhiwei Wang, Peiliang Wu, Yuhan Zhao, Deming Kong

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2026-05 · 353 · 127607

DOI: 10.1016/j.saa.2026.127607 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2026-05. Verfasst von Zhiwei Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Artificial Intelligence (School of Software), Yanshan University, Qinhuangdao 066004, China. Hauptthemen laut MEDLINE: Petroleum, Water Pollutants, Chemical. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Yanshan University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Submerged oil remains suspended in water bodies for extended periods, exhibiting high concealment and significant hazards. Accurate quantification of its concentration is crucial for formulating emergency response strategies. Accordingly, a comparative evaluation was carried out to examine the performance of four multi-way calibration strategies for the quantitative determination of submerged oil concentrations using time-resolved fluorescence spectroscopy (TRFS) data. The investigated approaches included parallel factor analysis/alternating penalty trilinear decomposition combined with partial least squares regression (PARAFAC/APTLD-PLSR), N-way partial least squares (N-PLS), as well as N-PLS combined with residual bilinearization (N-PLS/RBL). The results indicate that the N-PLS/RBL approach effectively leverages the ability of N-PLS to capture multidimensional spectral information while simultaneously benefiting from the second-order advantage introduced by the RBL algorithm. Consequently, this method exhibits superior prediction accuracy and greater robustness compared with the other calibration strategies. Among them, crude oil samples exhibited the most outstanding performance, with a residual predictive deviation (RPD) of 14.90 and a coefficient of determination of 0.99 for the validation set. In addition, the limits of detection (LOD) for the four oil types ranged from 0.15 to 1.03 mg·L-1, indicating high sensitivity that meets the requirements for rapid on-site detection. Overall, this study provides a reliable methodological foundation and technical pathway for the development of low-cost, highly interference-resistant, and rapid on-site detection technologies for submerged oil pollution.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PetroleumWater Pollutants, ChemicalSpectrometry, FluorescenceCalibrationLeast-Squares AnalysisLimit of DetectionAlgorithmsTime Factors

Stichwörter der Autor:innen

APTLD-PLSRN-PLSN-PLS/RBLPARAFAC-PLSRSubmerged oilTime-resolved fluorescence spectroscopy

Substanzen

PetroleumWater Pollutants, Chemical

Autor:innen und Institutionen

  • School of Artificial Intelligence (School of Software), Yanshan University, Qinhuangdao 066004, China.
  • School of Artificial Intelligence (School of Software), Yanshan University, Qinhuangdao 066004, China; Hebei Key Laboratory of Computer Virtual Technology and System Integration, Yanshan University, Qinhuangdao 066004,…
  • School of Electrical Engineering, Yanshan University, Qinhuangdao 066004, China; Tianfu cosmic ray research center, Institute of High Energy Physics of the Chinese Academy of Sciences, Chengdu 610299, China. Electronic…

Förderung

  • Yanshan University

Zitieren

APA

Wang, Z., Wu, P., Zhao, Y., & Kong, D. (2026). Quantitative determination of submerged oil concentrations by time-resolved fluorescence spectroscopy: A comparison of multi-way calibration strategies. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 353, 127607. https://doi.org/10.1016/j.saa.2026.127607

Vancouver

Wang Z, Wu P, Zhao Y, Kong D. Quantitative determination of submerged oil concentrations by time-resolved fluorescence spectroscopy: A comparison of multi-way calibration strategies. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2026;353:127607. doi:10.1016/j.saa.2026.127607

BibTeX
@article{Wang2026,
  author = {Wang, Zhiwei and Wu, Peiliang and Zhao, Yuhan and Kong, Deming},
  title = {Quantitative determination of submerged oil concentrations by time-resolved fluorescence spectroscopy: A comparison of multi-way calibration strategies},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2026},
  volume = {353},
  pages = {127607},
  doi = {10.1016/j.saa.2026.127607}
}