EUVIMEDEUVIMED entdecken
Crossref

Mercaptophenylboronic acid-modified double-layer PEI-Au magnetic probes: an ultrasensitive SERS biosensor for broad-spectrum bacterial capture and specific detection in clinical urine samples

Siyun Cheng, Jin Chen, Xiaodan Cheng, Shihui Zhu, Han Shen, Ping Yang, Rui Xiao

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2026

DOI: 10.1016/j.saa.2026.127544 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2026. Verfasst von Siyun Cheng und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China. Hauptthemen laut MEDLINE: Boronic Acids, Biosensing Techniques, Spectrum Analysis, Raman, Gold. Die Arbeit nennt 31 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Nanjing Drum Tower Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate identification of uropathogens is critical for guiding effective antibiotic treatment. In this study, we developed a surface-enhanced Raman spectroscopy (SERS) biosensor for rapid and sensitive detection of urinary pathogens. The system combines 4-mercaptophenylboronic acid (MPBA)-modified magnetic gold-shell beads (MSAuS@MPBA) for broad-spectrum bacterial capture with 5,5'-dithiobis(2-nitrobenzoic acid) (DTNB)- and antibody-functionalized gold nanoflowers (AuNFs@Ab) as SERS tags. A double-layer polyethyleneimine (PEI)-assisted 3 nm gold seed design was introduced to fabricate hierarchical rough surfaces on MSAuS@MPBA, significantly enhancing SERS signal generation through localized electromagnetic hotspots. The MSAuS@MPBA achieved capture efficiencies exceeding 87.52% for Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus (S. aureus). Using S. aureus as a model pathogen, the sandwich-type biosensor (MSAuS@MPBA/bacteria/AuNFs@Ab) exhibited a limit of detection (LOD) of 7 CFU mL-1, a wide linear range (101-106 CFU mL-1, R2 = 0.991), excellent specificity against five interfering urinary tract infection (UTI) bacteria, repeatability (RSD < 6.25%), and robust anti-matrix interference in urine and blood. Clinical validation using urine from UTI patients demonstrated high recovery rates (89.11-116.32%), confirming the sensor's practical applicability. This streamlined (∼50 min), ultrasensitive platform provides a clinically translatable method for point-of-care detection of urinary pathogens.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Boronic AcidsBiosensing TechniquesSpectrum Analysis, RamanGoldSulfhydryl CompoundsPolyethyleneimineBacteriaUrinary Tract InfectionsHumansLimit of Detection

Stichwörter der Autor:innen

4-Mercaptophenylboronic acid (MPBA)Gold nanoflowers (AuNFs)Staphylococcus aureus (S. aureus)Surface-enhanced Raman spectroscopy (SERS)Urinary tract infections (UTIs)

Substanzen

Boronic Acids4-mercaptophenylboronic acidGoldSulfhydryl CompoundsPolyethyleneimine

Autor:innen und Institutionen

  • Department of Clinical Laboratory, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China.
  • State Key Laboratory of Pathogen and Biosecurity, Academy of Military Medical Sciences, Beijing 100071, China.
  • Department of Clinical Laboratory, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China. Electronic address: shenhan@njglyy.com.
  • Department of Clinical Laboratory, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China. Electronic address: pingyang@njglyy.com.
  • State Key Laboratory of Pathogen and Biosecurity, Academy of Military Medical Sciences, Beijing 100071, China. Electronic address: ruixiao203@sina.com.

Förderung

  • National Natural Science Foundation of China
  • Nanjing Drum Tower Hospital

Zitieren

APA

Cheng, S., Chen, J., Cheng, X., Zhu, S., Shen, H., Yang, P., & Xiao, R. (2026). Mercaptophenylboronic acid-modified double-layer PEI-Au magnetic probes: an ultrasensitive SERS biosensor for broad-spectrum bacterial capture and specific detection in clinical urine samples. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2026.127544

Vancouver

Cheng S, Chen J, Cheng X, Zhu S, Shen H, Yang P, et al. Mercaptophenylboronic acid-modified double-layer PEI-Au magnetic probes: an ultrasensitive SERS biosensor for broad-spectrum bacterial capture and specific detection in clinical urine samples. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2026. doi:10.1016/j.saa.2026.127544

BibTeX
@article{Cheng2026,
  author = {Cheng, Siyun and Chen, Jin and Cheng, Xiaodan and Zhu, Shihui and Shen, Han and Yang, Ping and Xiao, Rui},
  title = {Mercaptophenylboronic acid-modified double-layer PEI-Au magnetic probes: an ultrasensitive SERS biosensor for broad-spectrum bacterial capture and specific detection in clinical urine samples},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2026},
  doi = {10.1016/j.saa.2026.127544}
}
Kostenlos starten →