Mercaptophenylboronic acid-modified double-layer PEI-Au magnetic probes: an ultrasensitive SERS biosensor for broad-spectrum bacterial capture and specific detection in clinical urine samples
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2026
DOI: 10.1016/j.saa.2026.127544 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2026. Verfasst von Siyun Cheng und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China. Hauptthemen laut MEDLINE: Boronic Acids, Biosensing Techniques, Spectrum Analysis, Raman, Gold. Die Arbeit nennt 31 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Nanjing Drum Tower Hospital.
Abstract (Originalsprache)
Accurate identification of uropathogens is critical for guiding effective antibiotic treatment. In this study, we developed a surface-enhanced Raman spectroscopy (SERS) biosensor for rapid and sensitive detection of urinary pathogens. The system combines 4-mercaptophenylboronic acid (MPBA)-modified magnetic gold-shell beads (MSAuS@MPBA) for broad-spectrum bacterial capture with 5,5'-dithiobis(2-nitrobenzoic acid) (DTNB)- and antibody-functionalized gold nanoflowers (AuNFs@Ab) as SERS tags. A double-layer polyethyleneimine (PEI)-assisted 3 nm gold seed design was introduced to fabricate hierarchical rough surfaces on MSAuS@MPBA, significantly enhancing SERS signal generation through localized electromagnetic hotspots. The MSAuS@MPBA achieved capture efficiencies exceeding 87.52% for Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus (S. aureus). Using S. aureus as a model pathogen, the sandwich-type biosensor (MSAuS@MPBA/bacteria/AuNFs@Ab) exhibited a limit of detection (LOD) of 7 CFU mL-1, a wide linear range (101-106 CFU mL-1, R2 = 0.991), excellent specificity against five interfering urinary tract infection (UTI) bacteria, repeatability (RSD < 6.25%), and robust anti-matrix interference in urine and blood. Clinical validation using urine from UTI patients demonstrated high recovery rates (89.11-116.32%), confirming the sensor's practical applicability. This streamlined (∼50 min), ultrasensitive platform provides a clinically translatable method for point-of-care detection of urinary pathogens.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Laboratory, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China.
- State Key Laboratory of Pathogen and Biosecurity, Academy of Military Medical Sciences, Beijing 100071, China.
- Department of Clinical Laboratory, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China. Electronic address: shenhan@njglyy.com.
- Department of Clinical Laboratory, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China. Electronic address: pingyang@njglyy.com.
- State Key Laboratory of Pathogen and Biosecurity, Academy of Military Medical Sciences, Beijing 100071, China. Electronic address: ruixiao203@sina.com.
Förderung
- National Natural Science Foundation of China
- Nanjing Drum Tower Hospital
Zitieren
APA
Cheng, S., Chen, J., Cheng, X., Zhu, S., Shen, H., Yang, P., & Xiao, R. (2026). Mercaptophenylboronic acid-modified double-layer PEI-Au magnetic probes: an ultrasensitive SERS biosensor for broad-spectrum bacterial capture and specific detection in clinical urine samples. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2026.127544
Vancouver
Cheng S, Chen J, Cheng X, Zhu S, Shen H, Yang P, et al. Mercaptophenylboronic acid-modified double-layer PEI-Au magnetic probes: an ultrasensitive SERS biosensor for broad-spectrum bacterial capture and specific detection in clinical urine samples. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2026. doi:10.1016/j.saa.2026.127544
BibTeX
@article{Cheng2026,
author = {Cheng, Siyun and Chen, Jin and Cheng, Xiaodan and Zhu, Shihui and Shen, Han and Yang, Ping and Xiao, Rui},
title = {Mercaptophenylboronic acid-modified double-layer PEI-Au magnetic probes: an ultrasensitive SERS biosensor for broad-spectrum bacterial capture and specific detection in clinical urine samples},
journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
year = {2026},
doi = {10.1016/j.saa.2026.127544}
}
EUVIMED