EUVIMEDEUVIMED entdecken
Crossref

Colorimetric and fluorometric dual-response system for rapid analysis of gentamicin in real samples

Guo Wei, Rui Wang, Peile Cao, Peng Zhang, Jinhua Li, Lingxin Chen, Zhihua Song

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2026

DOI: 10.1016/j.saa.2026.127461 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2026. Verfasst von Guo Wei und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Pharmacy, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Key Laboratory of…. Hauptthemen laut MEDLINE: Colorimetry, Gentamicins, Fluorometry, Anti-Bacterial Agents. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: Shandong Education Science Plan, Natural Science Foundation of Shandong Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Gentamicin (GENTA) have been extensively used by humans and animals, however, excessive GENTA resulted in environment and food contamination, and finally threatened human health. Therefore, it is very necessary to establish novel method for quantitative determination of GENTA in real samples. In this investigation, carbon dots incorporated with nitrogen and boron elements (N,B-CDs) with large stokes shift (125 nm) and high fluorescence intensity was designed, synthesized and utilized. In the process, 18 μL of the mixed solution was dropped onto the test strip each time; the test strip was tested by a smartphone and/or a miniaturized fluorimeter to achieve red (R), green (G), blue (B) and fluorescence intensity values after 1 min. The color and fluorescence intensity of the mixture changed obviously with gold nanoparticles (AuNPs) and GENTA adding. The limit of detection (LOD) of colorimetric and fluorometric dual-response system for GENTA was 0.30 μmol/L and 14.7 nmol/L, respectively. Furthermore, the selectivity and practicality of the system was assessed for other analytes (metal ions and other antibiotics) and real samples, respectively. The system showed excellent recovery (98.4%-103.9%) and outstanding repeatability (relative standard deviation (RSD), 1.2%-4.0%) for fluorometric determination of GENTA in real samples. Moreover, this system was suitable for colorimetric detection of GENTA (recovery, 94.8%-113.4%, RSD, 1.9%-7.9%). The good properties of N,B-CDs and miniaturized fluorimeter were combined for fluorescence determination of GENTA in real samples. And simple colorimetric detection of GENTA could be realized. In brief, we anticipate that this hybrid system could be useful for rapid and onsite detection of GENTA in environment, food, and pharmaceutical samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ColorimetryGentamicinsFluorometryAnti-Bacterial AgentsLimit of DetectionCarbon Quantum DotsMetal NanoparticlesSpectrometry, FluorescenceGoldReproducibility of ResultsHumansFood Contamination

Stichwörter der Autor:innen

Colorimetric and fluorometric dual-response systemFood samplesGentamicin (GENTA)Lake waterPharmaceuticalsTest strips

Substanzen

GentamicinsAnti-Bacterial AgentsGold

Autor:innen und Institutionen

  • School of Pharmacy, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Key Laboratory of Molecular Pharmacology and Drug Evaluation (Yantai University), Minis…
  • Coastal Zone Ecological Environment Monitoring Technology and Equipment Shandong Engineering Research Center, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China. Electronic addr…
  • Coastal Zone Ecological Environment Monitoring Technology and Equipment Shandong Engineering Research Center, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China.

Förderung

  • Shandong Education Science Plan
  • Natural Science Foundation of Shandong Province
  • National Natural Science Foundation of China
  • Shandong University of Science and Technology

Zitieren

APA

Wei, G., Wang, R., Cao, P., Zhang, P., Li, J., Chen, L., & Song, Z. (2026). Colorimetric and fluorometric dual-response system for rapid analysis of gentamicin in real samples. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2026.127461

Vancouver

Wei G, Wang R, Cao P, Zhang P, Li J, Chen L, et al. Colorimetric and fluorometric dual-response system for rapid analysis of gentamicin in real samples. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2026. doi:10.1016/j.saa.2026.127461

BibTeX
@article{Wei2026,
  author = {Wei, Guo and Wang, Rui and Cao, Peile and Zhang, Peng and Li, Jinhua and Chen, Lingxin and Song, Zhihua},
  title = {Colorimetric and fluorometric dual-response system for rapid analysis of gentamicin in real samples},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2026},
  doi = {10.1016/j.saa.2026.127461}
}
Kostenlos starten →