EUVIMEDEUVIMED entdecken
Crossref

Measurement and validation of high-temperature CO spectral line parameters near 2.3 μm using TDLAS for combustion diagnostics

Shujing Ruan, Guangzhen Gao, Yubing Yang, Hui Yang, Tingdong Cai

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2025-03 · 329 · 125577

DOI: 10.1016/j.saa.2024.125577 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2025-03. Verfasst von Shujing Ruan und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Physics and Electronic Engineering, Jiangsu Normal University, Xuzhou 221116, PR China. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Xuzhou Science and Technology Program, National Natural Science Foundation of China, Science and Technology Support Program of Jiangsu Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate determination of spectral parameters for carbon monoxide (CO) transitions is crucial for the development of laser absorption spectroscopy-based CO sensors. This study reports the measurement of line strengths, self-broadening coefficients, and their temperature-dependent exponents for three transitions in the first overtone band near 2.3 μm. These transitions were selected for their strong absorbance and minimal interference from other major combustion species, such as H2O and CO2, making them particularly suitable for combustion diagnostics. High-resolution absorption spectra of the selected CO transitions were recorded over a temperature range of 300-1100 K using a distributed-feedback (DFB) tunable diode laser. The spectral data were fitted to derive the aforementioned key spectroscopic parameters with high precision. To verify the accuracy and applicability of these parameters, a CO sensor employing multi-pass absorption spectroscopy was developed. This sensor was used to infer CO concentration in a C2H4/air flame based on the direct absorption spectrum of the CO line at 4300.699 cm-1, confirming the reliability of the measured parameters. The findings offer valuable spectroscopic data to support the development of advanced laser-based CO sensors, particularly for high-temperature applications.

Schlagwörter

Stichwörter der Autor:innen

Carbon monoxideHigh temperatureLine strengthSelf-broadening coefficientTunable diode laser absorption spectroscopy

Autor:innen und Institutionen

  • College of Physics and Electronic Engineering, Jiangsu Normal University, Xuzhou 221116, PR China.
  • College of Physics and Electronic Engineering, Jiangsu Normal University, Xuzhou 221116, PR China. Electronic address: ggz@jsnu.edu.
  • College of Physics and Electronic Engineering, Jiangsu Normal University, Xuzhou 221116, PR China. Electronic address: caitingdong@126.com.

Förderung

  • Xuzhou Science and Technology Program
  • National Natural Science Foundation of China
  • Science and Technology Support Program of Jiangsu Province

Zitieren

APA

Ruan, S., Gao, G., Yang, Y., Yang, H., & Cai, T. (2025). Measurement and validation of high-temperature CO spectral line parameters near 2.3 μm using TDLAS for combustion diagnostics. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 329, 125577. https://doi.org/10.1016/j.saa.2024.125577

Vancouver

Ruan S, Gao G, Yang Y, Yang H, Cai T. Measurement and validation of high-temperature CO spectral line parameters near 2.3 μm using TDLAS for combustion diagnostics. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2025;329:125577. doi:10.1016/j.saa.2024.125577

BibTeX
@article{Ruan2025,
  author = {Ruan, Shujing and Gao, Guangzhen and Yang, Yubing and Yang, Hui and Cai, Tingdong},
  title = {Measurement and validation of high-temperature CO spectral line parameters near 2.3 μm using TDLAS for combustion diagnostics},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2025},
  volume = {329},
  pages = {125577},
  doi = {10.1016/j.saa.2024.125577}
}