EUVIMEDEUVIMED entdecken
Crossref

Acriflavine-modified UIO-66 ratiometric fluorescent sensor for highly selective and fast detection of hypochlorite in water

Shili Qin, Yu Gao, Ming Zhao, Ying Wang, Minghui Zhai, Mo Chen, Xidi Xu, Chunqi Hu, Jinxin Lei, Hongtao Chu, Lidi Gao, Fenglong Jin

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2025-02 · 327 · 125333

DOI: 10.1016/j.saa.2024.125333 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2025-02. Verfasst von Shili Qin und 11 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Chemical Engineering, Qiqihar University, Qiqihar 161006, PR China; Technology Innovation Center of Industrial Hemp for Stat…. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 56 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hypochlorite (ClO-) as a kind of highly toxic pollutant has garnered significant interest in detection methods, highlighting the pressing need to develop intelligent functional materials for the qualitative and quantitative analysis of ClO- in aqueous solutions. Herein, a ratiometric fluorescent sensor was prepared by the combination of acriflavine (Acr) and UIO-66 via a post-synthetic modification strategy. Acr/UIO-66 exhibited both high crystallinity typical of metal-organic frameworks and demonstrated good fluorescent and thermal stability. Additionally, Acr/UIO-66 functioned effectively as a dual-responsive fluorescent platform for detecting ClO- in domestic drinking and surface water samples. This material displayed high sensitivity, exceptional selectivity, and superior anti-interference capabilities, along with fast respond time (60 s), a wide pH range (4.0-7.0), high recoveries (94.46-118.00 %), a broad linear range (0-28 µmol L-1) and low detection limits (0.74 µmol L-1). This study broadened the potential applications of fluorescent metal-organic frameworks and presented a feasible solution for water quality monitoring.

Schlagwörter

Stichwörter der Autor:innen

AcriglavineHypochloriteMetal-organic frameworkRatiometric fluorescent sensor

Autor:innen und Institutionen

  • College of Chemistry and Chemical Engineering, Qiqihar University, Qiqihar 161006, PR China; Technology Innovation Center of Industrial Hemp for State Market Regulation, Qiqihar 161006, PR China; Heilongjiang Industrial…
  • College of Chemistry and Chemical Engineering, Qiqihar University, Qiqihar 161006, PR China.
  • Qiqihar Inspection and Testing Center, Qiqihar Administration for Market Regulation, Qiqihar 161000, PR China. Electronic address: 02901@qqhru.edu.cn.

Zitieren

APA

Qin, S., Gao, Y., Zhao, M., Wang, Y., Zhai, M., Chen, M., Xu, X., Hu, C., Lei, J., Chu, H., Gao, L., & Jin, F. (2025). Acriflavine-modified UIO-66 ratiometric fluorescent sensor for highly selective and fast detection of hypochlorite in water. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 327, 125333. https://doi.org/10.1016/j.saa.2024.125333

Vancouver

Qin S, Gao Y, Zhao M, Wang Y, Zhai M, Chen M, et al. Acriflavine-modified UIO-66 ratiometric fluorescent sensor for highly selective and fast detection of hypochlorite in water. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2025;327:125333. doi:10.1016/j.saa.2024.125333

BibTeX
@article{Qin2025,
  author = {Qin, Shili and Gao, Yu and Zhao, Ming and Wang, Ying and Zhai, Minghui and Chen, Mo and Xu, Xidi and Hu, Chunqi and Lei, Jinxin and Chu, Hongtao and Gao, Lidi and Jin, Fenglong},
  title = {Acriflavine-modified UIO-66 ratiometric fluorescent sensor for highly selective and fast detection of hypochlorite in water},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2025},
  volume = {327},
  pages = {125333},
  doi = {10.1016/j.saa.2024.125333}
}
Kostenlos starten →