The optimization of sample preparation on zebrafish larvae in vibrational spectroscopy imaging
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2025
DOI: 10.1016/j.saa.2024.125288 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2025. Verfasst von Grzegorz Kalisz und 2 weiteren Autor:innen. Beteiligte Einrichtung: Independent Unit of Spectroscopy and Chemical Imaging, Medical University of Lublin, Chodzki 4a Street, 20-093 Lublin, Poland; Department of Bioanaly…. Hauptthemen laut MEDLINE: Zebrafish, Spectrum Analysis, Raman, Larva. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 82 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical University of Lublin.
Abstract (Originalsprache)
The zebrafish (Danio rerio) larvae are widely used in biomedical, pharmaceutical, and ecotoxicological studies. Their transparency and translational potential make them particularly valuable for fluorescence imaging. In addition to fluorescence imaging, microspectroscopy, which combines vibrational spectroscopy: Raman or Fourier transform infrared (FT-IR) with microscopy, allows the collection of spatially resolved, label-free information. According to available literature, it was the first application of FT-IR imaging in zebrafish larvae. This study aims to compare different fixation methods for 10-day post-fertilization (dpf) zebrafish larvae using vibrational spectroscopy imaging. Paraformaldehyde (PFA), glutaraldehyde (GA), low temperature, and embedding in gelatin and agarose were investigated. Amides, lipids, and phosphates distribution were more informative in embedded samples but with challenging handling of the sample due to stiffness at -20 °C. FT-IR and Raman mapping revealed that frozen samples had better-preserved tissue structure than chemical fixation. PFA showed uniform amide distribution, while GA treatment exhibited tissue disruptions and denser protein networks in both. Handling of embedded samples is challenging for an operator, but provides more reliable results in developmental biology or disease modeling, compared to chemical treatment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Independent Unit of Spectroscopy and Chemical Imaging, Medical University of Lublin, Chodzki 4a Street, 20-093 Lublin, Poland; Department of Bioanalytics, Medical University of Lublin, Jaczewskiego 8b Street, 20-090 Lub…
- Independent Unit of Behavioral Studies, Medical University of Lublin, Chodzki 1 Street, 20-093 Lublin, Poland. Electronic address: barbara.budzynska@umlub.pl.
- Independent Unit of Spectroscopy and Chemical Imaging, Medical University of Lublin, Chodzki 4a Street, 20-093 Lublin, Poland. Electronic address: anna.sroka-bartnicka@umlub.pl.
Förderung
- Medical University of Lublin
Zitieren
APA
Kalisz, G., Budzynska, B., & Sroka-Bartnicka, A. (2025). The optimization of sample preparation on zebrafish larvae in vibrational spectroscopy imaging. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2024.125288
Vancouver
Kalisz G, Budzynska B, Sroka-Bartnicka A. The optimization of sample preparation on zebrafish larvae in vibrational spectroscopy imaging. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2025. doi:10.1016/j.saa.2024.125288
BibTeX
@article{Kalisz2025,
author = {Kalisz, Grzegorz and Budzynska, Barbara and Sroka-Bartnicka, Anna},
title = {The optimization of sample preparation on zebrafish larvae in vibrational spectroscopy imaging},
journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
year = {2025},
doi = {10.1016/j.saa.2024.125288}
}
EUVIMED