Raman spectroscopy combined with machine learning and chemometrics analyses as a tool for identification atherosclerotic carotid stenosis from serum
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2025
DOI: 10.1016/j.saa.2024.125198 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2025. Verfasst von Jan Jakub Kęsik und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular Surgery and Angiology, Medical University of Lublin, Poland. Electronic address: jan.kesik@umlub.pl. Hauptthemen laut MEDLINE: Spectrum Analysis, Raman, Carotid Stenosis, Machine Learning, Principal Component Analysis. Die Arbeit nennt 28 Literaturangaben.
Abstract (Originalsprache)
Atherosclerosis carotid stenosis (ACS) is one of the main causes of stroke. Unfortunately, the highest number of people go to the doctor with an advanced disease or as a result of a stroke, because carotid atherosclerosis does not cause obvious symptoms. Therefore, it is important to find a diagnostic method to detect the disease during routine tests (using blood or serum). Consequently, in this article, Raman spectroscopy was tested as a potential diagnostic method. Indeed, Raman spectra of serum collected from ACS and control patients showed decrease of Raman peak around 1520 cm-1 and increase of peak around 3050 cm-1 in people with ACS. Moreover in people with ACS shift of peaks originating from amides II, I and lipids vibrations were noticed in comparison with control group. Interestingly, decision tree algorithm showed that peaks at 1656 cm-1 and 2957 cm-1 could be a spectroscopy markers of atherosclerotic carotid stenosis. Continuing, Principal Component Analysis (PCA) clearly showed distinguishing between serum collected from ACS and control patients, while machine learning algorithms showed high value of accuracy, sensitivity and selectivity (more than 90 %). Finally, value of area under the curve of Receiver Operating Characteristic (AUC-ROC) showed value of 0.81 for Raman range between 800 cm-1 and 1800 cm-1 and 0.86 for 2800 cm-1-3000 cm-1 range. Obtained results clearly showed possibility of Raman spectroscopy in detection of ACS from serum.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Vascular Surgery and Angiology, Medical University of Lublin, Poland. Electronic address: jan.kesik@umlub.pl.
- Institute of Computer Science, College of Natural Sciences, University of Rzeszow, Poland.
- Department of Vascular Surgery and Angiology, Medical University of Lublin, Poland.
- Institute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland.
- Institute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland; Department of Biochemistry and Molecular Biology, Medical University of Lublin, Poland. Electronic address: joanna.depciuch@ifj.edu.pl.
Zitieren
APA
Jakub Kęsik, J., Paja, W., Terlecki, P., Iłżecki, M., Klebowski, B., & Depciuch, J. (2025). Raman spectroscopy combined with machine learning and chemometrics analyses as a tool for identification atherosclerotic carotid stenosis from serum. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2024.125198
Vancouver
Jakub Kęsik J, Paja W, Terlecki P, Iłżecki M, Klebowski B, Depciuch J. Raman spectroscopy combined with machine learning and chemometrics analyses as a tool for identification atherosclerotic carotid stenosis from serum. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2025. doi:10.1016/j.saa.2024.125198
BibTeX
@article{JakubKsik2025,
author = {Jakub Kęsik, Jan and Paja, Wiesław and Terlecki, Piotr and Iłżecki, Marek and Klebowski, Bartosz and Depciuch, Joanna},
title = {Raman spectroscopy combined with machine learning and chemometrics analyses as a tool for identification atherosclerotic carotid stenosis from serum},
journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
year = {2025},
doi = {10.1016/j.saa.2024.125198}
}
EUVIMED