A naphthyl appended ninhydrin based colorimetric chemosensor for Cu2+ ion: Detection of cysteine and ATP
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2024
DOI: 10.1016/j.saa.2024.124734 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2024. Verfasst von Anisha Mondal und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India. Hauptthemen laut MEDLINE: Copper, Colorimetry, Ninhydrin, Cysteine. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: Department of Science and Technology, Ministry of Science and Technology, India, North East Centre for Biological Sciences and Healthcare Engineering, Indian Institute of Technology Guwahati, Indian Institute of Technology Guwahati.
Abstract (Originalsprache)
A ninhydrin-based colorimetric chemosensor (LH) was synthesized using 3-hydroxy-2-naphthoic hydrazide and 11H-indeno[1,2-b]quinoxalin-11-one. It was characterized by spectroscopic and single crystal X-ray diffraction techniques. In a semi-aqueous (MeOH/HEPES) system, LH displayed a characteristic chromogenic change from colorless to yellow upon adding Cu2+ ion, with the appearance of a new peak at λmax = 460 nm. A 1:1 binding stoichiometry between LH and Cu2+ ion has been found, with LOD = 2.3 μM (145 ppb) and LOQ = 8 μM (504 ppb). Based on experimental results the formula of [Cu(L)Cl(H2O)2] (1) was assigned and this in-situ generated 1 was found to exhibit a discoloration of upon gradual addition of cysteine (LOD = 60 nM) as well as ATP (LOD = 130 nM) having 1:2 and 1:1 stoichiometry respectively. The LH was useful for recognition of Cu2+ ion in real water samples and on filter paper strips. A two-input-two-output logic gate circuitry was also constructed by employing 1 and cysteine. The DFT/TDDFT calculations performed on LH and 1 were consistent with experimental findings. The binding affinity of LH towards HSA and BSA were determined with HSA having greater affinity than BSA, which was also supported by theoretical calculations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India.
- Department of Chemistry, Indian Institute of Technology Guwahati, Guwahati 781039, Assam, India. Electronic address: mani@iitg.ac.in.
Förderung
- Department of Science and Technology, Ministry of Science and Technology, India
- North East Centre for Biological Sciences and Healthcare Engineering, Indian Institute of Technology Guwahati
- Indian Institute of Technology Guwahati
Zitieren
APA
Mondal, A., & Manivannan, V. (2024). A naphthyl appended ninhydrin based colorimetric chemosensor for Cu2+ ion: Detection of cysteine and ATP. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2024.124734
Vancouver
Mondal A, Manivannan V. A naphthyl appended ninhydrin based colorimetric chemosensor for Cu2+ ion: Detection of cysteine and ATP. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2024. doi:10.1016/j.saa.2024.124734
BibTeX
@article{Mondal2024,
author = {Mondal, Anisha and Manivannan, Vadivelu},
title = {A naphthyl appended ninhydrin based colorimetric chemosensor for Cu2+ ion: Detection of cysteine and ATP},
journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
year = {2024},
doi = {10.1016/j.saa.2024.124734}
}