EUVIMEDEUVIMED entdecken
Crossref

Inverse fitting direct absorption spectroscopy Technology: Simplified implementation and enhanced performance

Jiachen Sun, Fupeng Wang, Jun Chang, Lin Zhang, Jiankun Shao

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2024-11 · 320 · 124660

DOI: 10.1016/j.saa.2024.124660 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2024-11. Verfasst von Jiachen Sun und 4 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Explosion Science and Safety Protection, Beijing Institute of Technology, Beijing, PR China. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Ministry of Science and Technology of the People's Republic of China, China Postdoctoral Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The conventional direct absorption spectroscopy (DAS) technique has been plagued by the difficulty of obtaining accurate baseline, which is caused by photoelectric drift and the absence of non-absorbing regions in the transmitted light intensity signal. An inverse fitting direct absorption spectroscopy (IF-DAS) technique has been proposed to address this difficulty. The technique leverages the intrinsic nonlinear intensity response of tunable lasers to achieve baseline-free concentration measurements. It offers the advantages of being straightforward to implement, baseline-free, calibration-free, and resistant to photoelectric signal drift. Its efficacy was validated using an example under ambient temperature and atmospheric pressure conditions. The performance of the IF-DAS technique was compared with that of the conventional DAS technique through standard experimental tests. The results demonstrate that the IF-DAS technique is less susceptible to fluctuations in light intensity, exhibits superior linearity and accuracy, with an R2 value of 0.99986 and an overall error of less than 2%. This technique shows potential for application in harsh scenarios such as reactive flow fields and long-term engineering applications.

Schlagwörter

Stichwörter der Autor:innen

Baseline-freeCalibration-freeEasy-to-implementInverse fitting direct absorption spectroscopyPhotoelectric signal drift-resistant

Autor:innen und Institutionen

  • State Key Laboratory of Explosion Science and Safety Protection, Beijing Institute of Technology, Beijing, PR China.
  • College of Information Science and Engineering, Ocean University of China, Qingdao 266100, PR China.
  • School of Information Science and Engineering and Shandong Provincial Key Laboratory of Laser Technology and Application, Shandong University, Qingdao, PR China.
  • State Key Laboratory of Explosion Science and Safety Protection, Beijing Institute of Technology, Beijing, PR China. Electronic address: jkshao@bit.edu.cn.

Förderung

  • National Natural Science Foundation of China
  • Ministry of Science and Technology of the People's Republic of China
  • China Postdoctoral Science Foundation

Zitieren

APA

Sun, J., Wang, F., Chang, J., Zhang, L., & Shao, J. (2024). Inverse fitting direct absorption spectroscopy Technology: Simplified implementation and enhanced performance. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 320, 124660. https://doi.org/10.1016/j.saa.2024.124660

Vancouver

Sun J, Wang F, Chang J, Zhang L, Shao J. Inverse fitting direct absorption spectroscopy Technology: Simplified implementation and enhanced performance. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2024;320:124660. doi:10.1016/j.saa.2024.124660

BibTeX
@article{Sun2024,
  author = {Sun, Jiachen and Wang, Fupeng and Chang, Jun and Zhang, Lin and Shao, Jiankun},
  title = {Inverse fitting direct absorption spectroscopy Technology: Simplified implementation and enhanced performance},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2024},
  volume = {320},
  pages = {124660},
  doi = {10.1016/j.saa.2024.124660}
}
Kostenlos starten →